Technical data of BPS 8
Leuze electronic
BPS 8
12
TNT
35/7-2
4
V
Table 3.1:
General specifications
Environmental data
Operating temperature range
0 °C … -40 °C
Storage temperature range
-20 °C … -60 °C
Air humidity
Max. 90% rel. humidity, non-condensing
Vibration
IEC 60068-2-6, test Fc
Shock/continuous shock
IEC 60068-2-27, test Ea
Electromagnetic compatibility EN 61000-6-2:2005+AC:2005,
EN 61000-6-3:2007+A1:2011+AC:2012
Conformity
CE, CDRH
Certifications
1)
2)
UL 60950-1, CSA C22.2 No.60950-1
Bar code tape
Max. length (measurement
length)
10,000 m
3)
Ambient temperature
-40 °C … -120 °C
Mech. properties
Scratch and wipe resistant, UV resistant,
moisture resistant, partly chemical resistant
1)
For UL applications: use is permitted exclusively in Class 2 circuits according to NEC
2)
These sensors shall be used with UL Listed Cable assemblies rated 30V, 0.5A min, in the
field installation, or equivalent (categories: CYJV/CYJV7 or PVVA/PVVA7)
3)
Depends on the transmission protocol and on the configured resolution.