Mounting and installation
Leuze electronic
BPS 8
33
TNT
35/7-2
4
V
6.1.2
Cutting bar code tapes
If necessary, the BCB is cut at the indicated cut marks ((see figure 6.1)).
Figure 6.1: Cut mark on the bar code tape
NOTE
Bridging gaps!
Any mechanical gaps may have to be bridged when affixing the bar code tape.
Smaller gaps (up to around 10mm) can be covered with the tape.
For wider gaps we recommend cutting out the label over the gap at the marked cut
mark.
In chemically aggressive environments, the bar code tape should be cut out over
mechanical gaps. Since the tape is highly resistant to chemical loads only on the front
side, exposure of the adhesive side should be avoided.
BCB8
BCB8
BCB8
BCB8
BCB8
BCB8
000036
000039
000042
000045
000048
000051
A
A
Cut mark