Configuration / device parameters
Leuze electronic
BPS 8
81
TNT
35/7-2
4
V
Parameters
The switching input function
Pos. measurement start/stop
in the
Function
parameter
means:
• High level at the switching input starts the position measurement.
• Low level at the switching input stops the position measurement.
Parameter
Description
Value range
Default
Unit
CR
Digital
I/O mode
Defines whether the switching
input and output are activated
via the MA 8-01/MA 8-02 or
whether only the switching input
or only the switching output is
activated.
0: Not
released
1:
BPS 8 with MA 8-01/
MA 8-02 (switching
input + switching
output)
2: Switching
input
3: Switching
output
1
–
–
Inversion
The parameter defines the logic
of the applied signal. In case of
an inversion, an external HIGH
level is interpreted as an inter-
nal LOW level.
0:
No (active high)
1:
Yes (active low)
0
–
–
Mode
This parameter controls the
release of the switching input.
0: Off
1:
On
1
–
–
Debounce
time in [ms]
This parameter defines a
debounce time which is imple-
mented via software.
0 … 255
5
ms
–
Start-up
delay in
[ms]
The parameter influences the
timing during switch-on.
0 … 65535
0
ms
–
Pulse dura-
tion in [ms]
The parameter defines a mini-
mum time period before the sig-
nal is reset.
0 … 65535
0
ms
–
Switch-off
delay in
[ms]
The parameter defines a time
delay for the signal during
switch-off.
0 … 65535
0
ms
–
Function
The parameter specifies the
function which is to be activated
or deactivated by a status
change at the switching input.
0: No
function
2
–
–
1:
Teach preset
Position
detection
2:
Start/stop position
measurement
Control
3:
Stop position mea-
surement
Control
a
b
c
d
e
f
g
h
e
a
b