Electrical connection
Leuze electronic
BPS 8
48
TNT
35/7-2
4
V
7
Electrical connection
7.1
Safety notices for the electrical connection
The BPS 8 is connected via KD(S) S-M12-5A… M12 cables.
The corresponding mating connectors and ready-made cables are available as accessories
for all connections. For additional information, refer to Chapter 12.5 starting on Page 117.
CAUTION
Safety notices!
Connection of the device and cleaning must only be carried out by a qualified electri-
cian.
If faults cannot be cleared, the device should be switched off and protected against
accidental use.
Before connecting the device, be sure that the supply voltage agrees with the value
printed on the respective name plate of the BPS 8.
The power supply unit for the generation of the supply voltage for the BPS 8 and the
respective connection units must have a secure electrical insulation through double
insulation and safety transformers according to EN 60742 (corresponds to IEC 60742).
Ensure the device is correctly earthed. Unimpaired operation is only guaranteed when
the functional earth is connected properly.
CAUTION
Degree of protection IP 67!
Degree of protection IP 67 is achieved only if the connectors and caps are screwed into
place!