Configuration / device parameters
Leuze electronic
BPS 8
72
TNT
35/7-2
4
V
8.5.1
Control
Figure 8.5: Control tab
Description:
The control manages the timing of the position calculation by starting and stopping the
decoding. Control is performed depending on certain events such as the switching input or
time functions. Using parameters, the events which influence the states are determined.
Parameters
Parameter
Description
Value range
Default
Unit
CR
Start mode
The start mode determines by
which event the position mea-
surement is started.
1: After initialization
2: Via command or
switching input
2
–
Switching
input
Stop mode
The stop mode determines after
which event the position mea-
surement is stopped.
2: Time (Polling Interval)
3: Time with re-trigger-
ing function (polling
interval) via com-
mand or switching
input
4: Via command or switch-
ing input (the switching
input must be pro-
grammed for this pur-
pose)
3
–
Switching
input
Maximum
polling
interval
Time period after which the
scanning beam is switched off if
no polling takes place.
0 … 65,535
10,000
ms
a
h
b
h
c