Configuration / device parameters
Leuze electronic
BPS 8
78
TNT
35/7-2
4
V
8.5.3
Communication
Figure 8.8: Communication tab
Parameters
The 5 different binary protocols are described in a separate chapter (
cols for position value output"
).
Parameter
Description
Value range
Default
Unit
CR
Baud rate
Setting the baud
rate.
4:
1200
5:
2400
6:
4800
7:
9600
8:
19200
9:
38400
10: 57600
11:
62500
12:
115200
13:
187500
10
Baud
–
Data
mode
Setting of the data
mode.
1:
7 data bits, no parity, 2 stop bits
2:
7 data bits, even parity, 1 stop bit
3:
7 data bits, even parity, 2 stop bits
4:
7 data bits, odd parity, 1 stop bit
5:
7 data bits, odd parity, 2 stop bits
6:
8 data bits, no parity, 1 stop bit
7:
8 data bits, no parity, 2 stop bits
8:
8 data bits, even parity, 1 stop bit
9:
8 data bits, even parity, 2 stop bits
10: 8 data bits, odd parity, 1 stop bit
11: 8 data bits, odd parity, 2 stop bits
12: 8 data bits, no parity, 1 stop bit + WakeUp
bit
13: 9 data bits, no parity, 1 stop bit
6
–
–
Protocol
Setting the proto-
col type.
17: Binary protocol 2
18: Binary protocol 3
19: Binary protocol 1
20: Binary protocol 4
23: Binary protocol 6
19
–
–
Address
Sets the partici-
pant address for
the RS 485 net-
work.
0: Address 0
1: Address 1
2: Address 2
3: Address 3
0
–
–
a
b
c
d