Configuration using configuration codes
70
Technical description LSIS 22x
Leuze electronic
7.5.22
MaxiCode code selection
By reading in one of the following configuration codes, reading of the
MaxiCode
code type
is activated or deactivated. In addition, it is possible to configure the number of digits that
are to be read (value range for number of digits: 1 … 150, factory setting: 1 … 150).
Figure 7.45: Configuration codes for activating/deactivating the MaxiCode code type
Notice!
To set the minimum or maximum number of digits, please first read in the above configura-
tion code and then the digits for the desired number of digits (see "Programming codes for
the configuration" on page 92). Conclude parameter entry by reading in the
Save
program-
ming code.
Read code type MaxiCode ON
Read code type MaxiCode OFF
MaxiCode - standard settings
MaxiCode - minimum number of digits
MaxiCode - maximum number of digits