Specifications for Leuze end devices
110
MA 258
i
Leuze electronic
16.12 Modular interfacing unit MA 3x (S4 switch position C)
Specifications for the serial interface
Specifications for Command mode
To activate the Command mode, bit 0 must be set to 1 in control byte 0.
For further information, see chapter 11.1.3 "Command mode", figure 11.2.
Recommended settings
• Produced data/Consumed data:
dependent on the number of digits of the code that is to be read.
With an 18-digit bar code (+ 2 bytes of status bytes + 2 bytes of slave address), for
example, it is advisable to use the "64 bytes In/4 bytes Out" combination.
Notice!
In this switch position, the address of the multiNet slave is also transmitted in the first two
bytes of the data range!
Default parameter
MA 3x
Baud rate
9600
Data mode
8N1
Handshake
no
Protocol
framing protocol without acknowledgment
Frame
<STX> <Data> <CR> <LF>
Control bit
Meaning
Corresponds to
serial command
(ASCII)
0
Version query
v
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Reset parameters to default values
PC20
15
Device restart
H