Electrical connection
40
MA 258
i
Leuze electronic
7.4
BUS OUT
Table 7.4:
EtherNet/IP BUS OUT pin assignment
For the host connection of the MA 258
i
, the "KB ET - … - SSA" ready-made cables are
preferred, see table 14.4 Bus connection cable for the MA 258i on page 94.
Notice!
Ensure adequate shielding. For the devices and ready-made cables offered by
Leuze electronic, the shield is on PIN 1.
If you use user-configurable cables, note the following:
Notice!
Ensure adequate shielding. The entire connection cable must be shielded and earthed. The
signal lines must be stranded in pairs.
Use CAT 5 cable for the connection.
Notice!
For the MA 258
i
as standalone device or as the last participant in a linear topology, termi-
nation on the BUS OUT socket is
not
mandatory!
BUS OUT (4-pin socket, D-coded)
Pin
Name
Remark
1
TD+
Transmit Data +
2
RD+
Receive Data +
3
TD-
Transmit Data -
4
RD-
Receive Data -
Thread
FE
Functional earth (housing)
BUS OUT
TD+ 1
2
3
4
RD+
RD-
TD-
M12 socket
(D-coded)