Commissioning and configuration
84
MA 258
i
Leuze electronic
12.6.2.1 Configuration instance
In addition, all values of the configuration (including changes) must be entered manually as
hex/bin values into the "ControlerTags" *.C of the respective device, see "Setting MA param-
eters manually via the config assembly" on page 74.
Instance 118, attribute 3
Input assembly length 12 byte
Leuze-specific assembly
Byte 00+01:
Data mode
Byte 02+03:
Serial line mode
Byte 04+05:
Baud rate
Byte 06+07:
Data bits
Byte 08+09:
Parity
Byte 10+11:
Stop bits
Data Mode
Parameter value:
0
d
0000
h
= Transparent mode (default)
1
d
0100
h
= Collective mode
Byte 0+1: 0000
h
, LowByte first
Serial line mode
Parameter value:
0
d
0000
h
= Use rotary switch (default)
1
d
0100
h
= Use EDS settings
Byte 2+3: 0000
h
, LowByte first
Designation
Size
in bit
Data type
Default
(dec)
Min
(dec)
Max
(dec)
Access
Cl.
Inst.
Attr.
4
118
3
Data Mode
8
BYTE
0
0
1
Set
Serial line mode
8
BYTE
0
see below
0
1
Set
Baud Rate
8
BYTE
96
see below
3
1152
Set
Data Bits
8
BYTE
8
see below
7
8
Set
Parity
8
BYTE
1
see below
1
3
Set
Stop Bits
8
BYTE
1
see below
1
2
Set