Commissioning and configuration
88
MA 258
i
Leuze electronic
12.7.2
Specific features in the operation of an RFM/RFI
When using the MA 258
i
in connection with an RFID device, we recommend a data width
of at least 24 bytes to be able to transmit information to or from the reader in a telegram.
Shown here is a sample telegram for a write command in combination with an RFID device.
Notice!
Also note that all characters which are sent to a transponder are hex-encoded ASCII char-
acters. Each of these (hexadecimal) characters is, in turn, to be handled as an individual ASCII
character and converted to hexadecimal format for transmission via the fieldbus.
Example:
7
6
5
4
3
2
1
0
00
00
00
00
00
00
00
00
Control byte 0
00
00
00
00
00
00
00
00
Control byte 1
34
35
31
31
30
35
30
57
Data
00
00
34
37
33
37
35
36
HEX
57
30
35
30
31
31
35
34
36
35
37
33
37
34
CHAR
W
0
5
0
1
1
5
4
6
5
7
3
7
4
Plain text
T
e
s
t