Mounting
Leuze electronic
RSL 410
42
all dimensions in mm
1
Safety sensor
2
Template (markings on safety sensor)
3
Mounting location
4
Reference point for distance measurement and protective field radius
5
Area with unobstructed view; must remain free
Figure 7.1: Mounting taking the scanning range of 270° into consideration
all dimensions in mm
1
Scan level
2
Area with unobstructed view; must remain free (40 mm)
Figure 7.2: Mounting: area with unobstructed view
Determine whether you are going to install the safety sensor with or without the mounting system.
During mounting, use the four supplied M5 screws or four similar screws with a diameter of 5 mm, and
make certain that the mounting elements or mounting construction supports at least four times the
weight of the device with or without mounting system.
Have the appropriate tools at the ready and mount the safety sensor.
Install protective enclosures or safety bars if the safety sensor is in an exposed position.