Technical data
NOTICE
Additional technical data and notices on using the device can be found
in the operating instructions.
BCL 92
BCL 95
Operating voltage
10 … 30 V DC (SELV)
4.75 … 5.5 V DC (SELV)
Current consumption
(SELV power supply unit)
Peak current during start-
up
30 V: 80 mA
24 V: 100 mA
10 V: 250 mA
Max. 450 mA (peak)
Nominal 350 mA at
+5 V DC
Power consumption
2.5 W
1.75 W
Light source / Wavelength Laser / 655 nm (visible red light)
Laser class
1 (acc. to IEC 60825-1:2014)
Impulse duration
<120 µs
Maximum optical output
power (peak)
2.1 mW
Scanning rate
600 scans/s
Beam exit
Frontal or lateral
Reading distance
See
reading fields
Resolution
0.165 mm … 0.5 mm
(6.5 mil … 20 mil)
0.15 mm … 0.5 mm
(6 mil … 20 mil)
Code types
2/5 Interleaved
Code 39
Code 128
EAN 128
UPC-A/UPC-E
EAN Addendum
EAN-8/EAN-13
Codabar
Pharmacode (available upon consultation)
Code 32
Code 93
Interface type
RS 232
32
EN