BCL 92
BCL 95
Baud rate
4800 … 57600 Bd
Data format
Data bits: 7, 8
Parity: none, even, odd
Stop bits: 1, 2
Service interface
(fixed data format)
RS 232, 9600 Bd, 8 bit, no parity, 1 stop bit
<STX> Data <CR><LF>
Switching input/output
2 switching inputs
+12 V DC … +30 V DC
2 switching outputs
+10 V … +30 V, 20 mA
1 switching input 5 V DC
1 switching output
5 V … 30 V, 20 mA
Degree of protection
IP54
VDE protection class
III with SELV power supply unit
Housing
Diecast zinc
Weight
Approx 210 g
Net weight without con-
nection cable
Approx. 210 g
Dimensions
See
2
Ambient temp. (operation/
storage)
+5 °C … +40 °C / -20 °C … +60 °C
Relative humidity
Max. 90 % (non-condensing)
Vibration
IEC 60068-2-6, test Fc
Shock
IEC 60068-2-27, test Ea
Electromagnetic compati-
bility
EN 61326-1:2013-01
Conformity
CE, CDRH, UL
Certifications
UL 60950-1, CAN/CSA C22.2 No. 60950-1-07
CAUTION
UL applications!
For UL applications, use is only permitted in LPS/Class 2 circuits in ac-
cordance with the NEC (National Electric Code).