Electrical connection
Leuze electronic GmbH + Co. KG
MSI-SR5B
21
The following circuit shows the connection of an AOPD (laser scanner) in a danger zone safeguarding
system. With this circuit, a reset button can deactivate the start/restart interlock.
Figure 7.3: One type 4 AOPD with two safety-relevant transistor outputs, manual restart (RES), central
wiring
The following circuit shows the connection of an AOPD with safety-related relay output contacts in a
danger zone safeguarding system with contactor monitoring (EDM) in the button circuit. With this circuit,
a reset button can deactivate the start/restart interlock.
Figure 7.4: Two type 4 AOPDs, each with two normally open contacts, manual restart (RES) and con
-
tactor monitoring (EDM), separate supply lines to the AOPDs required, local wiring