Product description
Leuze electronic GmbH & Co. KG
CSL 505
12
3.5.3
Beam mode
Beam mode
Parallel
beams
Diagonal
beams
Single
crossed-
beam
scanning
Multiple
crossed-
beam
scanning
Multiple
crossed-
beam
scanning
Synchronizati
on beam
first or last
first or last
load
load
load
Number of
beams
n
2n-1
3n-2
4n-4
5n-6
Max. perm.
number of
phys. beams
(n)
160
80
54
41
33
Sketch
Table 2:
Beam mode
NOTE
•
A teach event must be performed after this parameter is changed.
•
A higher number of beams also increases the cycle time!
•
A total of max. 160 logical beams are possible.
Factory settings:
R
ec
ei
ver
Pin 1
Pin 3
Description
+24 V DC
GND
Only parallel beams
GND
+24 V DC
Parallel and diagonal beams