Connecting the IT 3800g to the USB interface (COM-port emulation)
The operation of the IT 3800g as a serial interface on a USB port is described in this chapter. A COM interface is emulated in this
operating mode. The data which are read in are sent to a new COM interface. The driver with which you emulate this COM interface
can be downloaded from our homepage at
www.leuze.de. Thus, the data can be processed further in programs which expect data
via COM interfaces.
required parts:
1x
501 07 041
IT 3800g 15E
1x
501 03 404
USB cable
Procedure:
1.
Plug the IT 3800g hand-held scanner into a free USB
port.
2.
The scanner acknowledges this connection with a beep.
3.
Scan the barcode shown below.
4.
Install the USB serial driver when you are prompted to do
so by Windows.
5.
Open a terminal program or your program for the serial
interface, select the new COM port, and make the follow-
ing settings: baud rate 38,400, 8 data bits, 1 stop bit, no
parity, terminator <CR>.
USB COM-port emulation