Leuze electronic GmbH + Co. KG
Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730
IT 3800g - 02
www.leuze.de
Leuze
electronic
Connecting the IT 3800g to the serial PC interface
With voltage supply via PIN 9 with TTL-RS232-cable/PIN9 IT 4xxx Part No. 501 04586
required parts:
1x
501 07 041
IT 3800g 15E
1x
501 04 586
Cable TTL-RS232/PIN9
With voltage supply via power supply unit with cable RS232/ext IT 4xxx Part No. 501 04442
required parts:
1x
501 07 041
IT 3800g 15E
1x
501 04 442
Cable TTL-RS232/ext
1x
501 03 403
Power supply unit
Procedure:
1.
Switch off the PC.
2.
Connect the interface cable to a free COM port
(RS 232) on the computer, to the IT 3800g as well as to
the power supply unit.
3.
Switch the PC back on.
4.
Scan the adjacent barcode.
The IT 3800g is set to the following transmission
parameters:
RS 232 transmission with 38,400 baud, 8 data bits, 1 stop bit, no parity, terminators <CR><LF>.
5.
If necessary, adjust the transmission parameters of the used COM port to those of the IT 3800g.
Attention!
We recommend connecting the IT 3800g directly to a PC or to the MA 21 or MA 41… connector units. If connecting to
other components, please note that a voltage level range of -12 … +12V is maintained on the data lines!
IT 3800g