background image

Leuze electronic GmbH + Co. KG

Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730

IT 3800g - 02

www.leuze.de

Leuze 

electronic

Connecting the IT 3800g to the USB interface (keyboard emulation)

The operation of the IT 3800g in keyboard-emulation mode on a USB port is described in this section. A PC keyboard is emulated 
in this operating mode. The data which are read in are written directly to the currently activated program. Thus, the data can be 
processed further in all standard programs.

required parts:

1x

501 07 041

IT 3800g 15E

1x 

501 03 404 

USB cable

Procedure:

1.

Plug the IT 3800g hand-held scanner into a free USB 
port.

2.

The scanner acknowledges this connection with a beep.

3.

Scan the barcodes shown below.

USB keyboard emulation with CR LF

Keyboard layout for Germany/Austria

IT 3800g

Hand-held barcode scanner

Summary of Contents for IT 3800g

Page 1: ...rt No 501 03409 z USB cable for IT 4xxx Part No 501 03404 z Power supply unit for IT 4xxx Part No 501 03403 z Support for IT 3800g Part No 501 07039 Dimensioned drawing Electrical connection for RS 23...

Page 2: ...Dimensions 150x112x79mm Shock resistance 50 falls from a height of 1 5m Environmental data Ambient temp operation 0 C 50 C Ambient temp storage 40 C 60 C Relative air humidity 0 95 non condensing Pro...

Page 3: ...pointing the scanning surface towards a flat surface and pulling the trigger A red target line should now be visible Now scan a sample label The scanner emits an audible signal to confirm that the lab...

Page 4: ...3800g deactivates itself The second option is activation via the built in trigger button Configuration for the Leuze standard protocol To set the Leuze standard protocol you must first reset the scan...

Page 5: ...pply unit Procedure 1 Switch off the PC 2 Connect the interface cable to a free COM port RS 232 on the computer to the IT 3800g as well as to the power supply unit 3 Switch the PC back on 4 Scan the a...

Page 6: ...al in the MA 41 brown RXD 2 white TXD 1 blue GND 4 red VCC black GND bare shield PE 21 Procedure 1 Connect cable KB 021 Z to the MA 41 acc to the above pin assignments 2 Connect the interface cable to...

Page 7: ...ed VCC 30 black GND 31 bare shield PE 21 Procedure 1 Connect cable KB 021 Z to the MA 21 acc to the above pin assignments 2 Connect the interface cable to cable KB 021 Z 3 Scan the adjacent barcode Th...

Page 8: ...n directly to the currently activated program Thus the data can be processed further in all standard programs required parts 1x 501 07 041 IT 3800g 15E 1x 501 03 409 PS 2 cable Procedure 1 Switch off...

Page 9: ...lated in this operating mode The data which are read in are written directly to the currently activated program Thus the data can be processed further in all standard programs required parts 1x 501 07...

Page 10: ...de Thus the data can be processed further in programs which expect data via COM interfaces required parts 1x 501 07 041 IT 3800g 15E 1x 501 03 404 USB cable Procedure 1 Plug the IT 3800g hand held sca...