background image

Decora Plus Single Receptacle Outlet

Commercial Specification Grade, Tamper-Resistant

Cat. No. 16351-

SG

20A-125V Grounding

PK-A3292-10-02-0A

1

 

a

TO SIDE WIRE: 

   

 Strip wires 5/8 in (1.6 cm). Connect wires by looping stripped ends 
clockwise 3/4 turn around terminal screws and tighten securely. 

 

• Connect hot (black) wire to brass screw.

   

• Connect neutral (white) wire to silver screw.

   

• Connect green or bare copper wire to green screw.

   NOTE

: This device must be properly grounded.

  b

.

 TO BACK WIRE:

   

 

Strip wire per gauge on back of receptacle.  Depress screw to clear back 
wire holes.  Push stripped wires fully into hole and tighten securely.

   • 

 

Connect hot (black) wire to brass screw.

         • Connect neutral (white) wire to silver screw.
   

• Connect green or bare copper wire to green screw.

   NOTE

: This device must be properly grounded.

2

.   

Mount device with mounting screws. Attach wall plate.  

3

.  

Restore power.

INSTALLATION

ENGLISH

For Technical Assistance Call: 1-800-824-3005 (USA Only)  or 1 800 405-5320 (Canada only)www.leviton.com

LIMITED 1 YEAR WARRANTY AND EXCLUSIONS

Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials 
and workmanship under normal and proper use for one year from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at 
its option. 

For details visit www.leviton.com or call 1-800-824-3005.

 This warranty excludes and there is disclaimed liability for labor for removal of this product 

or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in 
any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. 

There are no other or implied warranties 

of any kind, including merchantability and fitness for a particular purpose

, but if any implied warranty is required by the applicable jurisdiction, the duration 

of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to one year. 

Leviton is not liable for incidental, indirect, 

special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to 
perform this warranty obligation

. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.

FOR CANADA ONLY

For warranty information and/or product returns, residents of Canada should contact Leviton in writing at 

Leviton Manufacturing of Canada ULC to the 

attention of the Quality Assurance Department, 165 Hymus Blvd, Pointe-Claire (Quebec), Canada H9R 1E9

 or by telephone at 

1 800 405-5320.

WARNINGS:
•  TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER

 

AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE 
POWER IS OFF BEFORE WIRING! 

•  To be installed and/or used in accordance with appropriate 

electrical codes and regulations. 

•  If you are not sure about any part of these instructions, consult 

an electrician.

•  Use this device only with 

copper

 or 

copper clad

 wire. 

Silver

Argent

Plateado

Green

Vert

Verde

125V

Brass

Laiton

Latón

Prise Decora Plus à une sortie

Inviolable, de qualité commerciale spécifiée

No de cat. 16351-SG

20 A-125 V, avec mise à la terre

AVERTISSEMENTS: POUR ÉVITER LES RISQUES D’INCENDIE, DE 
DÉCHARGE OU D’ÉLECTROCUTION, COUPER LE COURANT 

 AU FUSIBLE 

OU AU DISJONCTEUR ET S’ASSURER QUE LE CIRCUIT EST BIEN COUPÉ 
AVANT DE PROCÉDER À L’INSTALLATION!  

REMARQUE

 : les bornes acceptent les fils d’un calibre de 14 à 10 AWG

a

CÂBLAGE LATÉRAL :

         Dénuder les fils sur 5/8 po (1,6 cm). Relier les fils aux bornes en 

les enroulant autour de trois quarts de tour vers la droite; serrer 
fermement les vis.

        •  Relier le fil actif (noir) à la borne laitonnée.
        •  Relier le fil neutre (blanc) à la borne argentée.
        •  Relier le fil de terre (vert ou dénudé) à la borne verte.

AVERTISSEMENTS:
•  POUR ÉVITER LES RISQUES D’INCENDIE, DE DÉCHARGE 

OU D’ÉLECTROCUTION, COUPER LE COURANT 

 AU 

FUSIBLE OU AU DISJONCTEUR ET S’ASSURER QUE 
LE CIRCUIT EST BIEN COUPÉ AVANT DE PROCÉDER À 
L’INSTALLATION! 

•  Le produit décrit aux présentes doit être installé et utilisé 

conformément aux codes de l’électricité en vigueur.

•  À défaut de bien comprendre les présentes directives, en tout 

ou en partie, on doit faire appel à un électricien.

•  N’utiliser ce dispositif qu’avec du fil de 

cuivre ou  

plaqué cuivre

  REMARQUE

 : ce dispositif doit être mis à la terre 

adéquatement.

 b

.

 CÂBLAGE ARRIÈRE :

      Dénuder les fils conformément au gabarit à l’arrière de la 

prise. Enfoncer les vis pour dégager les orifices de câblage. 
Relier les fils aux bornes en les insérant dans les orifices; 
serrer fermement les vis.

     •  Relier le fil actif (noir) à la borne laitonnée.
     •  Relier le fil neutre (blanc) à la borne argentée.
     •  Relier le fil de terre (vert ou dénudé) à la borne verte.

REMARQUE

 : ce dispositif doit être mis à la terre adéquatement.

2.   

Fixer le dispositif au moyen des vis. Poser la plaque murale.  

3.  

Rétablir le courant.

WARNING:

 

TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER 

AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE 

POWER IS OFF BEFORE WIRING! 

NOTE:  Terminals accept #14-10 AWG wire.

INSTALLATION

FRANÇAIS

WEB 

VERSION

Reviews: