Single Pole (One location) or 3-Way (Multi-location)

Incandescent Slide Dimmer

Cat. No. IPIØ6-1L, 600W (Lighted)

Cat. No. IPI1Ø-1L, 1000W (Lighted)

120VAC, 60Hz

INSTALLATION INSTRUCTIONS

PK-93182-10-00-2B

Tools needed to install your Dimmer:

Slotted/Phillips Screwdriver

Electrical Tape

Pliers

Pencil

Cutters

Ruler

Color Change Option:

If a color change kit is provided with your device, proceed with the
following step if you need to change the color. Otherwise, proceed with
the "Installing Dimmer by itself or with other devices" section.

Changing the color of your Dimmer

Your Dimmer includes color options. To change color of frame, proceed
as follows:

Move the slider up or down one full cycle to automatically engage the
slider control mechanism.

Installing Dimmer by itself or with other devices:

If installing Dimmer in a single device application, proceed with the
INSTALLING YOUR  DIMMER section. If installing Dimmer in a multi-
device application, proceed as follows:

MULTI-DEVICE APPLICATION

NOTE: You only need to remove side sections if installing with other
dimmers or if it does not fit in wall box – not when installing with
mechanical switches.

When installing more than one dimmer in the same location, the side
sections of the mounting strap must be removed. Use pliers to carefully
bend side sections back and forth until they break off. The side sections
dissipate heat, so removing them requires a derating of the dimmer's
capacity (refer to chart).

INSTALLING YOUR DIMMER

NOTE: Use check boxes       when Steps are completed.

WARNING:

 To avoid fire, shock, or death; TURN OFF

POWER at circuit breaker or fuse and test that power is off
before wiring!

Step 2

Removing existing switch:

 Remove existing

wallplate and switch mounting screws. Carefully pull switch
from wall box. DO NOT remove wires attached to the switch
at this time.

Identifying your wiring application (most
common):

NOTE: If the wiring in the wall box does not resemble any of
these configurations, consult a qualified electrician.

Step 4

Disconnecting switch wires and preparing wires:

More than

 Cat. No.

 Single

Two Devices

2 Devices

 IPIØ6-1L

  600W

    500W

400W

 IPI1Ø-1L

  1000W

    800W

700W

MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE

Step 1

Step 3

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

Single-Pole:
Look at the back of your switch.
If there are 2 wires connected to
two screw terminals (not
including a green or bare copper
wire used for grounding), you
have a Single-Pole switch.

Step 3
cont'd

3-Way:
Look at the back of your switch.
If there are 3 wires connected to
three screw terminals (not
including a green or bare copper
wire used for grounding), you
have a 3-Way switch. Note that
one of the screw terminals will
usually be a different color
(black) or labeled Common. Tag
that wire with electrical tape to
identify.

Tag Common

Screw Wire

Push in side at tab
to release

Line up tabs and press
in side to attach

WARNINGS:

• To be installed and/or used in accordance with appropriate electrical codes and regulations.

• If you are unsure about any part of these instructions, consult a qualified electrician.

• To avoid overheating and possible damage to this device and other equipment, do not install to

control a receptacle, fluorescent lighting, a motor- or a transformer-operated appliance.

• Use with incandescent or 120V halogen fixtures only.

CAUTIONS:

• Use only one (1) dimmer in a 3- or 4-way circuit. The switch(es) will turn the light on at the brightness

level selected at the dimmer.

• Disconnect power at circuit breaker or fuse when servicing fixture.

• Use this device only with copper or copper clad wire. With aluminum wire use only devices marked

CO/ALR or CU/AL.

Bend back and
forth to remove side section

Remove
all inner
side
sections

Do not
remove
outer
side
sections

Disconnect wires from screw terminals or
Quickwire™ slots (shown).

Pull off pre-cut insulation from Dimmer leads.

Make sure that the ends of the wires from the
wall box are 

straight (cut if necessary).

Remove 5/8" (1.6 cm) of insulation from each
wire in the wall box (shown).

For Single-Pole Application, go to Step 5A.

For 3-Way Application, go to Step 5B.

Strip 5/8"
(1.6 cm)

Cut

(if necessary)

Press in slot and
pull out wire

Strip Gage

5/8"
(1.6cm)