Single Pole (One location) or 3-Way (Multi-location)
Incandescent Touch Dimmer
120VAC, 60Hz
Cat. No. TTIØ6-1, 600W
Cat. No. TTI1Ø-1, 1000W
For use w/ Cat. No. TT00R-1 True Touch
TM
Remote
INSTALLATION INSTRUCTIONS
WARNINGS AND CAUTIONS:
• To be installed and/or used in accordance with appropriate electrical codes and regulations.
• If you are unsure about any part of these instructions, consult a qualified electrician.
• To avoid overheating and possible damage to this device and other equipment, do not install to
control a receptacle, fluorescent lighting, a motor- or a transformer-operated appliance.
• Total minimum wattage must exceed 40W.
WARNINGS AND CAUTIONS:
• Use only one (1) dimmer per load. For remote operation, use Leviton Remote, Cat. No. TT00R-1.
Do not use a 3-way switch.
• Use with incandescent or 120V halogen fixtures only.
• Disconnect power at circuit breaker or fuse when servicing fixture.
• Use this device only with copper or copper clad wire. With aluminum wire use only devices marked
CO/ALR or CU/AL.
Tools needed to install your Dimmer:
Slotted/Philips Screwdriver
Electrical Tape
Pliers
Pencil
Cutters
Ruler
Changing the color of your Dimmer:
Your Dimmer includes two color options. The Dimmer ships with the
White frame attached. To change color of frame, proceed as follows:
When installing more than one dimmer in the same location, the side
sections of the mounting strap must be removed. Use pliers to carefully
bend side sections back and forth until they break off. The side sections
dissipate heat, so removing them requires a derating of the dimmer’s
capacity
(refer to chart).
Installing Dimmer by itself or with other devices:
If installing Dimmer in a single device application, proceed with the
INSTALLING YOUR DIMMER
section. If installing Dimmer in a multi-
device application, proceed as follows:
MULTI-DEVICE APPLICATION:
NOTE:
You only need to remove side sections if installing with other
dimmers or if it does not fit in wall box – not when installing with
mechanical switches.
Single-Pole:
Look at the back of your switch.
If there are 2 wires connected
to two screw terminals (not
including a green or bare copper
wire used for grounding), you
have a Single-Pole switch.
3-Way:
Look at the back of your switch.
If there are 3 wires connected
to three screw terminals (not
including a green or bare copper
wire used for grounding), you
have a 3-Way switch.
DO NOT
add a single-pole switch in this
location.
INSTALLING YOUR DIMMER
NOTE:
Use check boxes when Steps are completed.
WARNING:
To avoid fire, shock, or death;
TURN OFF
POWER
at circuit breaker or fuse and test that power is off
before wiring!
Step 1
Removing existing switch:
Remove existing
wallplate and switch mounting screws. Carefully pull switch
from wall box. DO NOT remove wires attached to the switch
at this time.
Identifying your wiring application (most common):
NOTE:
If the wiring in the wall box does not resemble any of
these configurations, consult a qualified electrician.
Step 2
Step 3
Push in side at tab
to release
Line up tabs and
press in side to attach
Bend back and
forth to remove side
section
Remove all
inner side
sections
Do not
remove
outer
side
sections
MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE
More than
2 Devices
Two Devices
Single
Cat. No.
400W
500W
600W
TTI06-1
700W
800W
1000W
TTI10-1
��
���
��
���
��
���
��
���
��
���
��
���
��
���
��
���
��
���
��
���
��
���
��
���
PK-92939-10-00-0B
Step 3
con’t
Tag Common Screw Wire
(screw is usually black and/or
marked "common")
Disconnecting switch wires and preparing wires:
• Disconnect wires from screw terminals or
Quickwire™ slots (shown).
• Pull off pre-cut insulation from Dimmer leads.
• Make sure that the ends of the wires from the
wall box are
straight (cut if necessary).
• Remove 5/8" (1.6 cm) of insulation from each
wire in the wall box (shown).
•
For Single-Pole Application, go to Step 5a.
• For 3-Way Application, go to Step 5b.
5/8"
(1.6 cm)
Strip Gage
Press in slot and
pull out wire
Step 4
Cut
(if necessary)
Strip 5/8"
(1.6 cm)
NOTE:
Ensure cut-out for Air-Gap Switch is positioned on bottom.
Cut-out for Air
Gap Switch