SEPARATE FEED (Two Line Hot)

Single pole switch and 3-way switch on two separate circuits. Light(s) 
controlled by single pole switch, other light(s) controlled by 3-way switch 
and another 3-way switch at a different location. Break-off fi n 

removed.

Step 4a

Complete Installation:

•   

Carefully position all wires to provide room in wall box for switch      

    Mount switch into wall box with mounting screws supplied.

•   Attach wallplate (sold separately) and restore power.    

   

    

INSTALLATION IS COMPLETE.

Step 5

Connect wires per WIRING DIAGRAM as follows.

•  Loop wires clockwise 3/4 turn around terminal screws.

•  Green or bare copper wall box wire (Ground) to Green  screw.

•  Black wall box wire (LINE 1 - HOT) to Black screw (Common).

•  Black wall box wire (LINE 2 - HOT) to remaining Black screw (Common).

•  Remaining black wall box wire (Load) to Brass screw (B1).

•  Traveler wires to Brass screws (A1 and A2).    

•  Tighten screws over wire loops with a force of 12-14 in.-lbs. of torque.

Terminal screws accept up to #12 AWG copper or copper clad wire.

•  For technical assistance contact us at 

1-800-824-3005

•  Visit our website at 

www.leviton.com

LIMITED 2 YEAR WARRANTY AND EXCLUSIONS

Leviton warrants to the original consumer purchaser and not for the benefi t of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper 
use for two years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option, if within such two year period the product is returned prepaid, with proof of 
purchase date, and a description of the problem to 

Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591.

 This warranty excludes 

and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, 
or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and 
fi tness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fi tness for a particular purpose, is limited 
to two years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profi ts or delay or failure to perform 
this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.

Connect wires per WIRING DIAGRAM as follows.

NOTE:  

For separate feed installations (TWO LINE HOT) proceed to 

Step 4a.

•  Loop wires clockwise 3/4 turn around terminal screws.

•  Green or bare copper wall box wire (Ground) to Green screw.

•  Black wall box wire (LINE HOT) to any Black screw (Common).

•  Remaining black wall box wire (Load) to Brass screw (B1).

•  Traveler wires to Brass screws (A1 and A2).    

•  Tighten screws over wire loops with a force of 12-14 in-lbs. of torque.

Terminal screws accept up to #12 AWG copper or copper clad wire.

Test Installation:

RESTORE POWER AT CIRCUIT BREAKER OR FUSE.

FOR 3-WAY SWITCH

•   Operate top toggle (rocker) several times: Light(s) should turn
    on and  off.

•   Go to other 3-way switch location and operate toggle (rocker) several  
    times: Light(s) should turn on and off.

FOR SINGLE POLE SWITCH

•   Operate bottom toggle (rocker) several times: Light(s) should turn on  
    and off.

NOTE:

 If light(s) do not work properly, TURN OFF POWER and

re-check wiring connections. If light(s) still do not work, consult a
qualifi ed electrician.

Step 6

"

!

!

Break-off fi n
removed

1.  

Line 1 (Hot-System)

2.  

Line 2 (Hot-System)

3.  

Neutral (Optional)

4.  

Ground

5.  

Load - Single Pole

6.  

Travelers

     (To other 3-Way Switch)

TWO LINE HOT
(Separate Feed)

COMMON FEED (Single Line Hot)

Step 4
cont.

SEPARATE FEED (Two Line Hot)

Step 4a
cont.

PK-93604-10-00-0A