Preparing and connecting wires:

This 4-Scene controller can be wired using side wire terminal 
screws or through backwire openings. Choose appropriate wire 
stripping specifications accordingly.

Wiring Application:

Including 4-Scene Controller into Z-Wave

®

 

Network:

Restore Power:

Restore power at circuit breaker or fuse.

 

Installation is complete.

NOTES:

• 

If using a non-Leviton Programmer/Remote, refer to the Programmer/
Remote instruction sheet.

• 

4-Scene controllers incuded into a Z-Wave

®

 network must be 

updated after you have included all other devices.

• 

If using the VRCPG Install Checklist feature, go to step C.

A)

  If using a Leviton Z-Wave

®

 Programmer/Remote, Cat. No. VRCPG, 

press the Menu button and scroll down to System. Press the center 
button to select System Menu. Choose Advanced. Press the center 
button to select Advanced Install. Press the center button to <Include 
Node>.

B)

  If using VRCPG Programmer/Remote, you will be prompted to place 

4-Scene controller into programming mode. 

C)

  To access Program mode, press and hold 

buttons 1 and 3 

(refer to figure)

. Wait 

5 seconds until the LED turns Amber. 
Release the buttons and the LED will blink 
Amber. You are now in Programming mode. 

D)

  While standing close to the 4-Scene 

controller (approximately 1 ft.), press the 
center button on the Programmer/Remote 
to <Include> device in the network.

 

NOTE:

 If the LED on the 4-scene controller 

turns solid Red while including, there has 
been a communication error.

 

NOTE:

 Only one device may be included at 

any time.

E)

  The Primary Programmer/Remote will assign a Home ID, Node ID, 

and Name for this device.

 

NOTE:

 This information will be stored in the Programmer/Remote to 

be used for future reference.

 

NOTE:

 You may name or edit your device at this time.

F)

 

The 4-Scene controller is now installed in the network

.

WARNINGS AND CAUTIONS

:

• 

TO AVOID FIRE, SHOCK OR DEATH; TURN OFF POWER 

at circuit breaker or fuse and test that power is off before wiring!

•  To be installed and/or used in accordance with appropriate electrical codes and regulations.

•  If you are unsure about any part of these instructions, consult an electrician.

• Vizia RF +

®

 VRCS4 controller does not control a load, but provides scene control of areas within a Vizia RF +

®

 System.

•  ON/OFF LED for remote scene status.

WARNINGS AND CAUTIONS

:

•  Recommended minimum wall box depth is 2-1/2".

•  Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.

•  Can call up four (4) scene ON/OFF with advanced programming. 

•  For a complete set-up, a controller supporting the advanced Z-Wave

®

 scene features is needed, such as the advanced Programming Remote (VRCPG).

•  Use this device with 

copper or copper clad wire only

.

4-Scene Controller

Cat. No. VRCS4-M0

120/240 VAC, 50/60Hz

INSTALLATION INSTRUCTIONS

DI-031-VRCS4-02F

 Tools needed to install your 4-Scene Controller

Slotted/Phillips Screwdriver 

Electrical Tape 

Pliers 

 

Pencil 

  Cutters 

 Ruler

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

WARNING: 

TO AVOID FIRE, SHOCK OR DEATH; TURN 

OFF POWER 

at circuit breaker or fuse and test that power is off 

before wiring!

 

Step 1

 

Step 3

•  Make sure that the ends of the wires from the wall box are 

straight (cut if necessary).

5/8" 

(1.6 cm)

Strip Gage 
(measure bare 
wire here)

Cut 

(if necessary)

Back Wire (either hole may be used) 

Back wire openings accept #14-12 
AWG 

solid copper wire only

Side Wire Connection 

Side wire terminals accept 
#14-12 AWG 

solid copper wire only

.

WIRING 4-SCENE CONTROLLER:
Connect wires per WIRING DIAGRAM as follows:

•  Green or bare copper wire in wall box to Green terminal screw.
•  Line Hot wall box wire to terminal screw marked "BK".
•  Line Neutral wall box wire to terminal screw marked "WH".

+RW%ODFN

1HXWUDO:KLWH

/LQH

9$&

+]

%.

:+

*UHHQ

*URXQG

6FHQH&RQWUROOHU

 

Step 4

3

1

2

1.

  Line (Hot)

2.

  Neutral

3.

  Ground

Identifying your wiring application (most common):

NOTE:

 If the wiring in your wall box does not resemble this 

configuration, consult a qualified electrician.

 

Step 2

 INTRODUCTION

Leviton’s Vizia RF +

®

 components are designed to communicate 

with each other via Radio Frequency (RF) to provide remote control 
of your lighting. Using RF technology allows Leviton to provide the 
greatest signal integrity possible. Each module in Leviton’s Vizia RF +

®

 

component line is a Z-Wave

®

 enabled device. In a Z-Wave

®

 network, 

each device is designed to act as a router. These routers will re-transmit 
the RF signal from one device to another until the intended device 
is reached. This ensures that the signal is received by its intended 
device by routing the signal around obstacles and radio dead spots. 
This 4-Scene Controller is meant to control special scene enabled 
Z-Wave

®

 products. To control groups of devices that are mixed or do 

not support scene command class use the Leviton 4-Zone Controller 
(VRCZ4). Setting up this device requires specific advanced controller 
functionalities, your controller must be able to associate device to groups 
and must be able to control the scene controller configuration commands 
such as the advanced Programming Remote (VRCPG).

•   This is a Z-Wave

®

 Controller

•   Scene control without traveler wires 
•   Can call 4 scenes
•   ON/OFF LED 
•   Two way communication
•   RF reliability 
•   Compatible with other Z-Wave

®

 enabled devices

 FEATURES

 

Step 8

Changing the color of your 4-Scene Controller:

Your 4-Scene controller includes three color options. The controller ships 
with the White frame attached. To change color of frame, proceed as 
follows:

Line up tabs 
and press in 
side to attach

Push in 
side at tab 
to release

After frame is removed, remove existing push buttons and replace them 
with desired color change push buttons. To change the DIM/BRIGHT 
button, before mounting frame, press out DIM/BRIGHT button (bottom) 
from back of frame and press in from front of frame new DIM/BRIGHT 
button. To make IR capable, replace with a DIM/BRIGHT button that has 
the IR window. 

INSTALLING YOUR 4-SCENE CONTROLLER

NOTE:

 Use check boxes           when Steps are completed.

•  Position all wires to provide room in 

outlet wall box for device.

•  Ensure that the word “TOP” is facing up 

on device strap.

•  Partially screw in mounting screws in 

wall box mounting holes.

 

NOTE:

 Dress wires with a bend as 

shown in diagram in order to relieve 
stress when mounting device.

•  Restore power at circuit breaker or fuse. 

•  LED should turn ON.

 

If LED does not turn ON, refer to the 
TROUBLESHOOTING section.

Testing your 4-Scene Controller prior to 
mounting in wall box:

 

Step 5

Installation may now be completed by 
tightening mounting screws into wall box. 
Attach wallplate.

4-Scene Controller Mounting:

TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.

 

Step 6

 

Step 7

WEB 