WARNINGS AND CAUTIONS
:
• To be installed and/or used in accordance with appropriate electrical codes and regulations.
• If you are unsure about any part of these instructions, consult a qualified electrician.
• To avoid overheating and possible damage to this device and other equipment, use only with the appropriate Advance Transformer 120V Mark 10™ Powerline or Lutron Tu-Wire™
electronic ballasts for controlling the specific fluorescent lamps.
• When retrofitting Mark 10™ Powerline dimming ballasts into fixtures that originally had Instant Start ballasts, the sockets MUST be replaced with Rapid Start sockets to allow proper
dimmer operation and prevent damage to the dimmer ballast. Refer to the instructions provided with the ballast.
• Vizia™ dimmers are not compatible with standard 3-way or 4-way switches. They must be used with compatible Vizia™ remotes for multi-location dimming.
• Use only one (1) Vizia™ dimmer in a multi-location circuit with up to 9 coordinating remotes without LEDs or up to 4 matching remotes with LEDs. The remote(s) will turn the light on
at the brightness level selected at the dimmer.
WARNINGS AND CAUTIONS
:
• Lamps must be burned in at full intensity for 100 hours prior to dimming for proper dimming performance.
• For new installations, wire a test switch before installing dimmer.
• Total minimum load must exceed 40W.
• Dimmer may feel warm to the touch during normal operation.
• Recommended minimum wall box depth is 2-1/2".
• Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft (90 m).
• Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.
• Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.
Single Pole (One location) or 3-Way (Multi-location)
Fluorescent Dimmer (Lighted)
Cat. No. VZX10-1L, 1000VA
120VAC, 60Hz
For use with Mark 10
TM
Powerline
and Tu-Wire
TM
dimmable ballasts
INSTALLATION INSTRUCTIONS
IMPORTANT :
For 3-Way applications, note that one of the screw
terminals from the old switch being removed will usually be a different
color (Black) or labeled Common. Tag that wire with electrical tape and
identify as the common (Line or Load) in both the dimmer wall box and
remote wall box.
For non-standard wiring applications, refer
to Wire Nut and Connector Size Chart
1 - #12 w/ 1 to 3 #14, #16 or #18
2 - #12 w/ 1 or 2 #16 or #18
1 - #14 w/ 1 to 4 #16 or #18
2 - #14 w/ 1 to 3 #16 or #18
WIRE CONNECTOR / # OF COND.
COMBINATION CHART
DI-000-VZX10-02A
��
���
��
���
��
���
��
���
��
���
��
���
��
���
��
���
��
���
��
���
��
���
��
���
• For Single-Pole Application, go to Step 4a.
• For 3-Way Coordinating Remote (no LEDs) Application, go to Step 4b.
• For 3-Way Matching Remote (with LEDs) Application, go to Step 4c.
WIRING DIMMER:
Connect wires per WIRING DIAGRAM as follows:
• Green or bare copper wire in wall box to Green dimmer lead.
• Line Hot wall box wire to Black dimmer lead.
• Load wall box wire to Red dimmer lead.
• Line Neutral wall box wire to White dimmer lead.
• Yellow/Red wire should have Red insulation label affixed.
NOTE:
If insulating label is not affixed to Yellow/Red dimmer lead,
use electrical tape to cover.
•
Proceed to Step 5.
3-Way Wiring with Coordinating Remote
(no LEDs) Application:
Step 4b
BL
WH
YL/RD RD
Coordinating Remote
Dimmer
5
1
2
3
4
5
Green
Yellow/
Red
Red
Black
White
2
1
4
3
Hot (Black)
Neutral (White)
Dimmer
Coordinating Remote (no LEDs)
YL/RD
Yellow/Red
RD
White
Red
Black
Black
BL
WH
White
Ballast
Line
120VAC, 60Hz
Green
Ground
Primary
Side
(unused)
(unused)
Green
Ground
Screw
WIRING DIMMER:
Connect wires per WIRING DIAGRAM as follows:
NOTE:
When using the coordinating remote without LEDs, the dimmer
can be installed on either the Line or Load side of the 3-way circuit.
NOTE:
Maximum wire length from dimmer to all installed remotes
cannot exceed 300 ft (90 m).
• Green or bare copper wire in wall box to Green dimmer lead.
• Line Hot (common) wall box wire identified (tagged) when removing
old switch to Black dimmer lead.
• First Traveler wall box wire to Red dimmer lead
(note wire color)
.
• Remove Red insulating label from Yellow/Red dimmer lead.
• Second Traveler wall box wire to Yellow/Red dimmer lead
(note wire color)
. This traveler from the dimmer must go to the
terminal screw on the remote marked "YL/RD".
• Line Neutral wall box wire to White dimmer lead.
Lutron Tu-Wire
TM
:
To determine total ballast load, add the line current found on the ballast label
for all ballasts in the circuit. This will indicate the total load for the control.
Tools needed to install your Dimmer:
Slotted/Phillips Screwdriver
Electrical Tape
Pliers
Pencil
Cutters
Ruler
When installing more than one dimmer in the same location, the
side sections of the mounting strap must be removed. Use pliers to
carefully bend side sections back and forth until they break off. The
side sections dissipate heat, so removing them sometimes requires a
derating of the dimmer’s capacity
(refer to chart)
.
MULTI-DEVICE APPLICATION
NOTE:
You only need to remove side sections if installing with other
dimmers or if it does not fit in wall box – not when installing with
mechanical switches.
If installing Dimmer in a single device application, proceed with the
INSTALLING YOUR DIMMER
section. If installing Dimmer in a multi-
device application, proceed as follows:
Installing Dimmer by itself or with other devices:
Changing the color of your Dimmer:
Your Dimmer includes three color options. The Dimmer ships with the
White frame attached. To change color of frame, proceed as follows:
Line up tabs and
press in side to attach
Push in side at
tab to release
INSTALLING YOUR DIMMER
NOTE:
Use check boxes when Steps are completed.
WARNING:
TO AVOID FIRE SHOCK OR DEATH; TURN
OFF POWER
at circuit breaker or fuse and test that power
is off before wiring!
Step 1
2
4
3
1
2
4
1
5
3
Single Pole
1.
Line (Hot)
2.
Neutral
3.
Ground
4.
Load
3-Way
1.
Line or Load
(see important
instruction below)
2.
Neutral
3.
Ground
4.
First Traveler – note color
5.
Second Traveler – note color.
NOTE:
For matching remote
w/LEDs installation, the
First Traveler
becomes Line Hot.
Identifying your wiring application (most common):
NOTE:
If the wiring in your wall box does not resemble any
of these configurations, consult a qualified electrician.
Step 2
Cut
(if necessary)
5/8"
(1.6 cm)
Strip Gage
(measure bare
wire here)
Preparing and connecting wires:
Pull off pre-cut insulation from dimmer leads. Make sure that
the ends of the wires from the wall box are
straight (cut if
necessary)
. Remove insulation from each wire in the wall
box as shown:
Step 3
Dimmer
Insulating
Label
Black
Primary
Side
Ballast
Hot (Black)
Black
Line
120 VAC, 60Hz
Neutral (White)
Red
Yellow/Red
White
White
Green
Ground
Single Pole Wiring Application:
Insulating label:
This wire is used in 3-way installations only.
For single pole installations, do not remove
this insulating label.
1
4
2
3
Black
White
Green
Red
Yellow/Red
Step 4a
Cat. No. VZX1Ø-1, 120V, For use with Advance Transformer
120V Mark 10
TM
Powerline
Electronic Ballasts
Max. # Ballasts/Dimmer for
Multi-gang
Advance
Mark 10
TM
Powerline
Part No.
Lamp
Single
Gang
Two
Ganged
More than
2 Gang
REZ-2Q18-M2-LD
REZ-1T32
REZ-2Q26
REZ-1T32
REZ-1T42
REZ-1Q18-M2-BS
REZ-1Q18-M2-LD
REZ-2Q18-M2-BS
REZ-1T32
REZ-1T42-M2-BS
REZ-1T42-M2-LD
REZ-2Q26
REZ-2Q26-M2-BS
REZ-2Q26-M2-LD
REZ-1Q18-M2-BS
REZ-1Q18-M2-LD
REZ-2Q18-M2-BS
REZ-2Q18-M2-LD
REZ-1T42-M2-BS
REZ-1T42-M2-LD
REZ-2Q26-M2-BS
REZ-2Q26-M2-LD
REZ-1T42-M2-BS
REZ-1T42-M2-LD
REZ-2T42-M3-BS
CFTR32W/GX24Q
13
10
8
CFTR32W/GX24Q
26
20
16
CFTR32W/GX24Q
26
20
16
CFTR26W/GX24Q
17
13
11
CFTR26W/GX24Q
17
13
11
CFTR26W/GX24Q
32
25
20
CFTR26W/GX24Q
32
25
20
CFTR18W/GX24Q
23
18
15
CFTR18W/GX24Q
23
18
15
CFTR18W/GX24Q
46
37
30
CFTR18W/GX24Q
46
37
30
CFQ26W/G24Q
17
13
11
CFQ26W/G24Q
17
13
11
CFQ26W/G24Q
17
13
11
CFQ26W/G24Q
32
25
20
CFQ26W/G24Q
32
25
20
CFQ26W/G24Q
32
25
20
CFQ18W/G24Q
23
18
15
CFQ18W/G24Q
46
37
30
CFQ18W/G24Q
46
37
30
CFM42W/GX24Q
20
16
13
CFM32W/GX24Q
26
20
16
CFM26W/GX24Q
17
13
11
CFM26W/GX24Q
32
25
20
15
18
23
CFM18W/GX24Q
Step 4a cont'd
MAXIMUM BULB WATTAGE
Mark 10™
Powerline
dimmers are rated in Volt-Amps (VA). The maximum
bulb wattage is determined by the efficiency of the Mark 10™
Powerline
ballast. The following table shows the maximum number of ballasts that
can be connected to a single dimmer for different Mark 10™
Powerline
ballasts. Also note that the table shows maximum ballasts for multi-gang
installations.
MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE
More than
2 Devices
Two Devices
Single
Cat. No.
650VA (5.4 A)
800VA (6.6 A)
1000VA (8.3 A)
VZX1Ø