User Manual for BPS-2000
www.levitronix.com
PL-4021-00, Rev03, DCO# 15-235
20
Figure 22: Temperature curves of motor LPM-2000.2 with Air Cooling Module ACM-4.2
(Temperature is measured inside of the motor, temperature of housing and sensor electronics is significantly below this temperature)
77
97
117
137
157
177
197
0
5
10
15
20
25
30
35
25
35
45
55
65
75
85
95
0
20
40
60
80
100
120
140
[°F]
[gpm]
[
0
C]
[lpm]
Ambient Temp = 25
C
Liquid Temp. = 40
C
Specific gravity = 1 g/cm3
Viscosity = 0.7 cP
Air cooling with ACM-4.2
1 bar, ~25 C air
Absolute Temperature Limit
Recommended Operational Limit
7000 rpm
6000 rpm
5000 rpm
8000 rpm
4000 rpm
77
97
117
137
157
177
197
0
2
4
6
8
10
12
14
16
18
20
22
25
35
45
55
65
75
85
95
0
10
20
30
40
50
60
70
80
[°F]
[gpm]
[
0
C]
[lpm]
Ambient Temp = 25
C
Liquid Temp. = 40
C
Specific gravity = 1 g/cm3
Viscosity = 0.7 cP
Air cooling with ACM-4.2
1 bar, ~25 C air
Absolute Temperature Limit
Recommended Operational Limit
7000 rpm
6000 rpm
5000 rpm
10000 rpm
8000 rpm
9000 rpm
4000 rpm
High-Flow System
Pump Head LPP-2000.6
High-Pressure System
Pump Head LPP-2000.7