4.1.2 General Installation Instructions
!
WARNING
Hazardous voltage may be present.
Always isolate the electrical power supply before making or changing
connections to the unit.
In case of the usage of an inadequate AC/DC power supply, mains
voltages may be present (even if the system is designed for 48VDC).
The usage of a galvanic separated power supply, which is certified by
a 3
rd
party (UL or CE), is highly recommended.
!
WARNING
Hazardous voltage may be present.
The controller housing must be properly grounded and placed in a spill
protected electrical cabinet. Use one of the DIN-rail screws on the back
side of the controller housing.
Do not use different and longer screws, which may result in short-
circuit within the controller.
1.
The controller casing must be grounded. The screws of the DIN-rail brackets can be used for
grounding (see
).
2.
Connect the two motor connector
s (“Power Output” and “Sensoric”) to the controller.
3.
Connect the controller type specific connectors: see
Section 4.1.3
for standalone operation with the
LPC-600.1-01
,
Section 4.1.4
LPC-600.1-01
and
Section 4.1.5
extended operation with
LPC-600.2-01
4.
The pump system requires 48 DC supply voltage at a maximum power of 600 W. At a lower
performance power supplies with smaller power or bigger supplies to supply several pump systems
simultaneously may be used.
to get the power consumption depending on the
flow.
Contact Levitronix for consulting and support on the power supply solution.
5.
Connect the DC power supply connector with the cable (included in the controller delivery). Make
sure that the polarity is correct (see
) and that AC/DC power supply is off.
6.
To secure the connectors, tighten all retaining screws.
Figure 25: Grounding of LPC-600 controller