4.4 Mechanical Installation of the Controller
!
WARNING
Hazardous voltage may be present.
In order to avoiding fluid spills shorting mains or other voltages within
the controller, place the controller in a spill protected environment (for
example protected electronic cabinets).
If explosive flammable gases are present, place the controller in an
explosion-proof cabinet.
CAUTION
Make sure the controller is mounted in a position that allows free air
circulation around the controller. A minimum distance of 10cm (4”) to
other objects above or below the controller casing is recommended.
•
Use the Din-Rail bracket to mount the controller.
•
If no forced air-cooling is used, mount the controller in upright position.
•
The Din-Rail brackets can also be mounted on the controller side according to
CAUTION
Use only 3,5 x 6,5 mm self-tapping screw for the fixation of the Din-Rail
brackets.
The controller may be damaged if other type or too long
screw types are used!
4.5 Mechanical Installation of Adaptor/Extension Cables
For connecting the motor to the controller the adaptor cables
MCAP-600.x
(for power cable) and
MCAS-
600.x
(for sensor cable) shall be used (see
for adaptor cables). For the cables which use an M23
threaded metallic Hummel connector type check the correctness of the connection according to the following
pictures:
Figure 33: Wrong and correct Hummel connector type assembly
O-Ring visible
Wrong Connection!
O-Ring not visible
Correct Connection!
Gap > 2 mm
Sensor Cable
of Motor
Power Cable
of Motor
Gap > 1 mm
Gap
1 mm
Gap
2 mm
Sensor
Adaptor Cable
Power
Adaptor Cable