User Manual for BPS-200
www.levitronix.com
PL-4012-00, Rev07, DCO# 20-144
12
3.2 Power Supply and Consumption
shows the typical power consumption of the system. If other AC/DC power supplies than the
standard specified ones are used, it is recommended to evaluate them under demanding operating situations
like fast braking from maximum speed and during power on and take-off of the impeller.
Figure 11: Electrical power consumption
(Controller LPC-200.x with pump head LPP-200.1 and motor BSM-1.x. Representative for LPP-200.11)
3.3 Temperature Monitoring
To avoid overheating of the system, the controller and motor temperatures are monitored. If the controller
temperature exceeds
70°C
(158°F)
or the motor temperature
90°C
(194°F)
for a duration of more than 10
minutes, the system goes into an error state and the pump stops. At
80°C
(176 F)
controller temperature or
100°C (212°F)
motor temperature, the system stops immediately.
Start
Temperature
Monitoring
WARNING
YES
Temperature
> 70°C ?
Temperature
> 80°C ?
YES
YES
ERROR
Temperature
higher than 70°C
for more than 10
minutes?
NO
ERROR
YES
NO
NO
Start
Temperature
Monitoring
WARNING
YES
Temperature
> 90°C ?
Temperature
> 100°C ?
YES
YES
ERROR
Temperature
higher than 90°C
for more than 10
minutes?
NO
ERROR
YES
NO
NO
Figure 12: Controller temp. monitoring
Figure 13: Motor temperature monitoring
0.0
1.0
2.0
3.0
4.0
5.0
6.0
0
25
50
75
100
125
150
175
200
0.0
2.5
5.0
7.5
10.0
12.5
15.0
17.5
20.0
22.5
25.0
[gallons/min]
[Watts]
[liters/min]
Specific gravity = 1 g/cm
3
Viscosity = ~ 0.7 cP
Liquid Temp.: 40C
10000 rpm
9000 rpm
8000 rpm
7000 rpm
6000 rpm
5000 rpm
— Supply = 24 VDC
- - - Supply = 48 VDC