9.1.5 ATEX / IECEx Certification and Marking
Specific motors together with the pump head of the
BPS-200
pump system are in conformity with the
requirements of the
Directive 2014/34/EU
and the relevant
IECEx
standards. The following standards are
tested and confirmed at a certified laboratory.
IEC / EN 60079-0
Electrical apparatus for explosive gas atmospheres. General requirements.
IEC / EN 60079-15
Electrical Apparatus for explosive gas atmospheres. Construction, test and marking of type of
protection, “nA” non-sparking electrical apparatus.
IEC / EN 60079-31
Explosive atmospheres
– Part 31: Equipment dust ignition protection by enclosure “t”.
IEC / EN 13463-1
Non-electrical equipment for use in potentially explosive atmospheres
– Part1: Basic method and
requirements.
IEC / EN 13463-5
Non-electrical equipment for use in potential explosive atmospheres
– Part5: Protection by
constructional safety “c”.
The Levitronix Ex motors are marked clearly and in accordance to the
ATEX
Directive and the relevant
IECEx
standards. The protection “Ex nA” means non sparking electrical apparatus.
II 3G Ex nA IIC T5 Gc
II 3D Ex tc IIIC T100°C Dc
Classification:
Category 3GD (Zone 2 for Gas and Zone 22 for Dust)
Thermal Classification:
Thermal classification of motor is T5 (< 100
0
C = 212
0
F) for maximum full-load operating
temperature at a maximum liquid temperature of 90
0
C / 194
0
F.