2.2 System Overview and General Specification
2.2.1 Stand-Alone System Configuration
The stand-alone configuration of the
BPS-200
pump system
, consists of a controller with an
integrated user panel to set the speed manually.
The speed is automatically stored in the internal EEPROM
of the controller. As an option, the speed can also be set with an analogue signal.
Figure 3: Standard system configuration for standalone operation
(Speed setting with integrated user panel)
2.2.2 Extended System Configuration
The extended version of the
BPS-200
pump system (
) consists of a controller with an extended PLC
interface. This allows setting the speed by an external signal and enables precise closed-loop flow or
pressure control in connection with either a flow or a pressure sensor. A USB interface allows
communication with a PC in connection with the
Levitronix
®
Service Software
. Hence parameterization,
firmware updates and failure analysis are possible.
Figure 4: Standard system configuration for extended operation
(Pressure or flow control with external sensor)
Chemical Resistance and IP67 Space
Motor
Pump Head
Fluid In
Fluid Out
Motor Cable
Adaptor/Extension
Power Supply
24-48 VDC
200 W
Controller
for
Standalone
Operation
Stand Alone
Operation
Speed Control
PLC Interface
Speed Setting
- 1x Digital Input (Enable)
- 1x Digital Output (Status)
- 1x Analog Input (Speed)
Chemical Resistance and IP67 Space
Motor
Pump Head
Fluid In
Fluid Out
Motor Cable
USB
- Service
- Firmware Update
- Configuration etc.
Flow- or
Pressure
Sensor
Adaptor/Extension Cable
Extended PLC Interface
Speed, Flow
or Pressure Setting
- 4 Digital Inputs
- 4 Digital Outputs
- 4 Analog Inputs
- 2 Analog Outputs
Power Supply
24-48 VDC / 200 W
Controller
for
Extended
Operation
1
2b
3a
4
1
2b
3b
4
Motor option with direct
cabling to controller
2a
Motor option with
Direct cabling
to controller
2a