User Manual for BPS-200
www.levitronix.com
PL-4012-00, Rev07, DCO# 20-144
8
2.4 Pressure-Flow Curves
Figure 6: Pressure/flow rate curves
(Measured with pump head LPP-200.1. Representative for LPP-200.11)
2.5 Maximum Static Pressure for Pump Heads
Figure 7: Specification for maximum static pressure of pump head LPP-200.1/11
- Pressure limits only valid for pump head mounted on motor.
- Pump head LPP-200.1/11 comes delivered with PVDF mounting screws.
- Stainless steel screws with PTFE coating can be ordered separately according to Table 4.
It is recommended to use stainless steel (SS) pump head screws, which are available as an accessory (see
), at higher liquid temperature or when hammering effects (dynamic static pressure peaks) are
expected, which might result in longer term deformation effects of the standard PVDF screws.
0
10
20
30
40
0.0
1.0
2.0
3.0
4.0
5.0
6.0
0.0
0.5
1.0
1.5
2.0
2.5
3.0
0.0
2.5
5.0
7.5
10.0
12.5
15.0
17.5
20.0
22.5
25.0
[psi]
[gallons/min]
[bar]
[liters/min
Specific gravity = 1 g/cm
3
Viscosity = 0.7 cP
Liquid Temp.: 40C
8000 rpm
7000 rpm
6000 rpm
5000 rpm
Supply Voltage: 24 V DC
Speed Limit for 24V
=
9500 rpm
Speed Limit for 48V = 10000 rpm
9000 rpm
10000 rpm
0
20
40
60
80
100
120
140
77
87
97
107
117
127
137
147
157
167
177
187
0
1
2
3
4
5
6
7
8
9
10
25
30
35
40
45
50
55
60
65
70
75
80
85
90
[psi]
[°F]
[bar]
Liquid Temperature in [°C]
Max. Static Pressure for LPP-200.1 (PTFE Housing with PVDF Pumphead Screws)
Max. Static Pressure for LPP-200.1 (PTFE Housing with Option SS Screws)
Safety Factor = 1.3 (according to EN12162)
Limitation: Given by deformation. Burst pressure is significantly higher
Ambient Temp = 25
C
Note: Pressure limit only valid for pumphead mounted on motor
Supply Voltage: 24 VDC
Supply Voltage: 48 VDC