9.1.7 Immunity to Voltage Sags
– Semi F47
Based on internally testing at
Levitronix
®
the pump system
BPS-2000
in its various configurations is able to
handle all the voltage sags defined in
SEMI F47
. Therefore the pump system
BPS-2000
full fills the
requirements of the
SEMI F47
standard. The nominal voltage range is 200
– 240 VAC ±10% for operation
without performance reduction. Based on this range the voltage sags specified in
SEMI F47
have an
influence on the maximum performance as following:
Specified Voltage Sag
Impact on the System
80% of equipment nominal
voltage, duration 1000 ms
No impact on the system operation mode since supply voltage is above
the warning level. Slight power drop at high flow rate and speed is
possible.
70% of equipment nominal
voltage, duration 500 ms
No impact on the system operation mode since supply voltage is above
the warning level; slight power drop at high flow rate and speed is
possible.
50% of equipment nominal
voltage, duration 200 ms
The system reduces the speed to 4000 rpm for save operation since
supply voltage is below the warning level.
After the disappearing of the voltage drop, the system is returning to its full performance.