User Manual for BPS-i100
www.levitronix.com
PL-4036-00, Rev03, DCO# 21-057
18
Figure 22: Temperature curves for the IPD-100.2-50 driver @ 70°C liquid temperature
Note 1 Typical data for pumping with pump head LPP-200.7 and IPD-100.x drivers.
Figure 23: Temperature for cooling with water cooling module WCM-100.1 @ 90°C liquid temp.
Note 1 Typical data for pumping with pump head LPP-200.7 and IPD-100.x drivers.
77
97
117
137
157
177
0.0
1.0
2.0
3.0
4.0
5.0
25
35
45
55
65
75
85
0.0
2.5
5.0
7.5
10.0
12.5
15.0
17.5
20.0
[°F]
[gallons/min]
[°C]
[liters/min]
Absolute Temperature Limit
Recommended Operational
Temperature Limit
5000 rpm
6000 rpm
7000 rpm
8000 rpm
9000 rpm
4000 rpm
Specific gravity = 1 g/cm
3
Viscosity = 0.7 cP
Ambient Temp.: 25
°C
77
97
117
137
157
177
0.0
1.0
2.0
3.0
4.0
5.0
25
35
45
55
65
75
85
0.0
2.5
5.0
7.5
10.0
12.5
15.0
17.5
20.0
[°F]
[gallons/min]
[°C]
[liters/min]
Absolute Temperature Limit
Recommended Operational Limit
5000 rpm
6000 rpm
7000 rpm
8000 rpm
9000 rpm
4000 rpm
Ambient Temp = 25
°C
Liquid Temp. = 90
°C
Specific gravity = 1g/cm
3
Viscosity = 0.7cP
Cooling with water cooling module WCM-100.1 and
cooling liquid flow = 0.5 l/min at 20
°C temperature.