User Manual for BPS-i100
www.levitronix.com
PL-4036-00, Rev03, DCO# 21-057
23
4.2 Electrical Installation of EasyConnect Model
4.2.1 Overview of Connections and Designations
Figure 27: Electrical connections to EasyConnect driver IPD-100.4/5
Pin #
Pin
Name
Wire
Color
1
Description
Standard
Designation
2
Specifications
Typical Levels
Note
B
P +
red
+ 24 VDC
Power Supply
Voltage: 24 VDC ±10%
Power: 100 W
“P -“ shall be connected to earth
A
P -
black
Ground/Earth
C
NC
white
Not connected
--
Wire of compatible cables is cut.
Wire of compatible cables is cut.
1-14
NC
--
Not connected
--
Wire of compatible cables is cut.
Wire of compatible cables is cut.
Table 10: Power supply connector of EasyConnect driver
1: Wire colors of compatible cables: ICP-2.1-xx.
2: Designations for standard firmware. For other firmware refer to relevant documentation.
Pin #
Pin
Name
Wire
Color
1
Description
Standard
Designation
Typical Levels
Note
3
GND
brown
Ground
--
--
--
black
shield
6
NC
pink
Not connected
--
--
--
blue
1
RS485+
white
RS485+
Fieldbus
Modbus protocol.
For remote control with other devices.
Usage of
Levitronix
®
Service Software
with a
RS485 to USB adaptor cable.
2
RS485-
yellow
RS485-
4
Internal
grey
Internal
Do not
connect.
--
Internal bus needed to connect pumps for serial
pumping.
5
Internal
red
Internal
Table 11: Fieldbus IN connector of EasyConnect driver
1: Wires of compatible cables: ICS-1.1-xx and ICS-1.2-xx
Pin #
Pin
Name
Wire
Color
1
Description
Standard
Designation
Typical Levels
Note
3
GND
brown
Ground
Supply
Output
24VDC 10%, 200 mA
(Max. current is together with Pout of
PLC
connector in
For supply of external devices (displays etc.).
Internally protected.
black
shield
6
Pout
pink
Output 24VDC
blue
1
RS485+
white
RS485+
Fieldbus
Modbus protocol.
For remote control with other devices.
Usage of
Levitronix
®
Service Software
with a
RS485 to USB adaptor cable.
Feed through for multi-pump arrays (for
example serial pumping, see
2
RS485-
yellow
RS485-
4
Internal
grey
Internal
Do not
connect.
--
Internal bus needed to connect pumps for serial
pumping.
5
Internal
red
Internal
Table 12: Fieldbus OUT connector of EasyConnect driver
1: Wires of compatible cables: ICS-1.1-xx and ICS-1.2-xx
Power Supply
Connector
PLC Connector
Fieldbus IN
Fieldbus OUT
Not used.