User Manual for PuraLev
®
2000SU
www.levitronix.com
PL-4034-00, Rev02, DCO# 20-144
13
3.2 AC Supply and Power Consumption
3.2.1 Power Consumption
Figure 13: Electrical power consumption for aqueous liquids
(Controller LPC-2000.x with pump-head DCP-2000.2)
3.2.2 AC Input Voltage and Grid Currents
The input grid currents depend on the operational point and the input voltage. As shown in
input grid currents are achieved at highest power and lowest voltage. Note that the grid currents also depend
on the impedance of the grid, therefore below values are only typical values.
Phase Type
AC Voltage
AC Input Current
Performance Mode
Single-phase
50/60Hz
200
– 240 VAC ±10%
Typical: 12
– 8.5 Arms ±10%
Max.
2
: 13.3
– 11.1 Arms ±10%
Continuous speed and
pressure with maximum
active power.
Three-phase
50/60Hz
Delta voltage
1
:
200
– 240 VAC ±10%
(180
– 264 VAC)
Star voltage
1
: 115
– 139 VAC ±10%
(104
– 153 VAC)
Typical: 3x 7
– 5 Arms ±10%
Continuous speed and
pressure with maximum
active power.
Table 8: Voltage and grid current specifications
Note 1: See Figure 24 for visualization of delta and star voltages.
Note 2: Values depend on impedance of grid.
3.2.3 Inrush Current
Various situations have to be considered for the inrush current. The controller has integrated inrush current
limiters, which limit the current during switch-on of the AC power. However, these limiters are not active if the
controller is not completely discharged
shows the inrush currents during these situations. It has to be
emphasized that these are absolute worst case currents measured with a rigid mains supply at highest input
voltage. In reality these inrush currents might be much smaller.
0
5
10
15
20
25
30
35
0
400
800
1200
1600
2000
0
20
40
60
80
100
120
140
[gpm]
[Watts]
[lpm]
Specific gravity = 1 g/cm
3
Viscosity = ~ 0.7 cP
Liquid Temp.: 40
C
7000 rpm
6000 rpm
5000 rpm
8000 rpm
4000 rpm