User Manual for PuraLev
®
2000SU
www.levitronix.com
PL-4034-00, Rev02, DCO# 20-144
16
Figure 18: Temperature curves of motor LPM-2000.x with Air Cooling Module ACM-4.2
(Temperature is measured inside of the motor, temperature of housing and sensor electronics is significantly below this temperature)
Figure 19: Temperature curves of motor LPM-2000.x with Fan Cooling Module FCM-2000.1
(Temperature is measured inside of the motor, temperature of housing and sensor electronics is significantly below this temperature)
77
97
117
137
157
177
197
0
5
10
15
20
25
30
35
25
35
45
55
65
75
85
95
0
20
40
60
80
100
120
140
[°F]
[gpm]
[°C]
[lpm]
Ambient Temp = 25
C
Liquid Temp. = 60
C
Specific gravity = 1 g/cm
3
Viscosity = 0.7 cP
Air cooling with ACM-4.2
Absolute Temperature Limit
Recommended Operational Limit
7000 rpm
6000 rpm
5000 rpm
8000 rpm
4000 rpm
77
97
117
137
157
177
197
0
5
10
15
20
25
30
35
25
35
45
55
65
75
85
95
0
20
40
60
80
100
120
140
[°F]
[gpm]
[°C]
[lpm]
Ambient Temp = 25
C
Liquid Temp. = 60
C
Specific gravity = 1 g/cm
3
Viscosity = 0.7 cP
Fan cooling with FCM-2000.1
(~25
C air )
Absolute Temperature Limit
Recommended Operational Limit
7000 rpm
6000 rpm
5000 rpm
8000 rpm
4000 rpm