Unpack the device without damaging it and check whether the device type corresponds 
to the one ordered. The packing should always follow the device until this has been 
permanently mounted.

Avoid direct sunlight, dust, high temperatures, mechanical vibrations and shock, and rain 
and heavy moisture.

Only technicians who are familiar with the technical terms, warnings, and 
instructions in the manual and who are able to follow these should connect the 
device.

Mounting and connection of the device should comply with national legislation for 
mounting of electric materials, i.e. wire cross section, protective fuse, and location.
Descriptions of input / output and supply connections are shown in this installation 
guide and on the side label.

Use this device only in accordance with this instruction manual, as well as all 
applicable local and national laws and regulations. Only allow this device to be 
installed, operated, maintained, repaired, etc. by others who have also read and 
understood the user manual. 

Do not allow minors, untrained personnel, or personnel suffering from physical or 
mental impairment that would affect their ability to follow this manual to install, 
operate, maintain, or repair this device.

Any untrained personnel who might be near the device while it is in operation 
MUST be informed that it is dangerous and fully instructed on how to avoid injury 
during its use.

SAFETY

 

INSTRUCTIONS

Summary of Contents for LSP-IV2 Series

Page 1: ...User Manual Lueta Nr 319 Romania 40758576007 o ce levtech ro www levtech ro Galvanic 0 10V or 0 5V Isolator LSP IV2...

Page 2: ...g 6 2 5 Cleaning 7 3 DESCRIPTION 8 4 FEATURES 8 5 INSTALLATIONAND WIRING 9 5 1 Installation onTS 35 DIN Rail 9 5 2 Connections with ScrewTerminals 9 6 SPECIFICATIONS 10 7 CONFIGURATIONTYPE AND ORDER C...

Page 3: ...ns about the operation and maintenance of this product please contact our customer support If a problem arise with the product check if you followed the installation steps correctly If the problem per...

Page 4: ...rovals Date Version Number Document Changes 11 03 2021 1 0 Initial draft 13 04 2021 2 0 Overall improvements 15 04 2021 3 0 Application examples added Name Title Levi Mihaly General Manager Document R...

Page 5: ...onal injury may result from not knowing and following these instructions In order to ensure long product life Levtech recommends that you utilize the product and perform maintenance by correctly follo...

Page 6: ...n the manual and who are able to follow these should connect the device Mounting and connection of the device should comply with national legislation for mounting of electric materials i e wire cross...

Page 7: ...xplosive atmospheres disconnect power before servicing and do not separate connectors when energized and an explosive gas mixture is present Do not mount or remove devices from the power rail when an...

Page 8: ...a 3 point galvanic isolator which means that the input output and the power supply is separated from each other This instrument is suitable for any industrial application where 0 10V or 0 5V analog s...

Page 9: ...ttach the module in the lower part of the rail as shown in the left gure below 2 Press the module upwards 1 Apply leverage using a screwdriver as shown in the right gure below 2 Press the module downw...

Page 10: ...perature Range 10 60 C Storage Temperature Range 30 80 C Humidity Level 0 95 RH at 40 C no condensation 10 10K Input Range 0 10V or 0 5V Input Resistance Number of inputs 1 General Output accuracy 0 1...

Page 11: ...24VDC 1 2 PS V 0 10 V 7 8 0 10 V LSP IV2 005 LSP IV2 010 1 Negative Signal Input 2 Positive Signal Input 3 Negative Input of the Power Supply 4 Positive Input of the Power Supply 5 Negative Signal Out...

Page 12: ...emens PLC through the LSP IV2 010 galvanic isolator 24V Z Min 1K Rs Isolation 15 30V 5V Rs 10k 0 10V V 0 10V 2 IN 8 OUT 4 U 1 IN 7 OUT 3 U 0 10V 0 10 V OUT RUN STOP U57 LOGO_AM2 L M L M I1 M1 U1 I2 M2...

Page 13: ...tion It is ideal for removing errors caused by noise and signal interference protecting sensitive equipment such as PLC form potentional hazards The module has voltage input and voltage output In the...

Page 14: ...defect will be made free of charge If you purchased the item from our distributors and it is under warranty please contact them to notify us of the situation Levtech Service Department will determine...

Page 15: ...vtech COMPANY DATA levtech_s_p levtechsp 14 CONTACT INFORMATION ADDRESS Lueta Nr 319 Post Code 537140 Harghita Romania LEVTECH SERVICE PRODUCTION SRL Fiscal code CIF RO35733217 Trade Register RC J19 1...

Reviews: