background image

1. Turn LUX knob clockwise to the maximum (SUN). Turn time knob anti-clockwise to the minimum.Turn 
sensor knob clockwise to the maximum.
2. Power connected, the load controlled will start working and stop working 2±1 seconds later when there is 
no continual signal detected. 
3. Once detected, the load works and the indicator on and stops working 10 seconds later when there is no 
continual signal detected.And if signal detected 4 seconds later, the load should start working and the 
indicator on and stop working 10 seconds later when there is no continual signal detected.
4. Turns LUX knob anti-clockwise to the minimum. If it is tested under the circumstance above 10LUX, load 
should not work after induction load stop working; but if you cover the detection window with opaque objects 
(towel etc), the load works. Under the condition of no induction signals, the load should stop working within 
10 sec.

Test

The load don’t work:

a. Please check the power and load connect is correct.

b. Check if the load is good.

c. Check if the show lamp accelerates its speed after detecting.

d. Check if the working light corresponds to the light-control.

The sensitivity is poor:

a. Please check if there is hinder in front of the detection window to effect receiving the signals.

b. Please check if the ambient temperature is too high.

c. Please check if the signals source is in the detection fields.

d. Please check if the installation height corresponds to the height showed in the instruction.

e. Please check if the moving orientation is correct.

The sensor can’t shut the load automatically:

a. Check if there are continual signals in the detection fields.

b. Check if the time setting is set to the longest.

c. Check if the power corresponds to the instruction.

d. Check if the temperature change obviously nears the sensor, such as air condition or central heating etc.



Avoid installing it near air temperature alteration zones such as air condition, central heating, etc.
Considering your safety, please don’t open the cover when you find the hitch after installation.
If there is difference between product and instruction, please refer to product mainly.

Some problem and solved way



Should be installed by electrician or experienced man.
Avoid installing it on the unrest objects.
There shouldn’t be hindrance and moving object in front of the detection window effecting detection.

Note

Adjust working light. Turn clockwise to increase it and turn anti-clockwise to decrease it. 
When turn to mini, it will only work below the light-control about 10LUX, when turn to 
max, it can work any light-control.

<10-2000LUX

(2)Light-control setting

Summary of Contents for LX-PR-65S-Z

Page 1: ...everal times This is why the conventional sensor on the market has a short life and a small load current In order to overcome this problem this product adopts advanced digital precision calculation to turn on the load when the sine wave is at zero potential thus solving the load surge current problem greatly enhancing the load capacity and prolonging the service life of the product The latest cont...

Page 2: ...d the light will keep on only if there is human in the detection range Knob adjustment 1 TIME adjuster adjust the light delay 2 LUX adjuster adjust level of light operation TIME Night Operation Day Operation LUX TIME 10sec 12min Connection wire diagram L brown N blue L red Connect L and N with power Connect L and N with load Sensor Brown Blue N L Load L Red Input Output LUX adjustment LUX refers t...

Page 3: ...f the detection window to effect receiving the signals b Please check if the ambient temperature is too high c Please check if the signals source is in the detection fields d Please check if the installation height corresponds to the height showed in the instruction e Please check if the moving orientation is correct The sensor can t shut the load automatically a Check if there are continual signa...

Page 4: ...cut off the power for safety purposes Improper operation caused losses the manufacturer does not undertake any responsibility This manual is for the current content programming of this product there are any changes and modifications to the manufacturer without notice This instruction without our permission should not be copied for any other purposes ...