1. Turn LUX knob clockwise to the maximum (SUN). Turn time knob anti-clockwise to the minimum.Turn
sensor knob clockwise to the maximum.
2. Power connected, the load controlled will start working and stop working 2±1 seconds later when there is
no continual signal detected.
3. Once detected, the load works and the indicator on and stops working 10 seconds later when there is no
continual signal detected.And if signal detected 4 seconds later, the load should start working and the
indicator on and stop working 10 seconds later when there is no continual signal detected.
4. Turns LUX knob anti-clockwise to the minimum. If it is tested under the circumstance above 10LUX, load
should not work after induction load stop working; but if you cover the detection window with opaque objects
(towel etc), the load works. Under the condition of no induction signals, the load should stop working within
10 sec.
Test
The load don’t work:
a. Please check the power and load connect is correct.
b. Check if the load is good.
c. Check if the show lamp accelerates its speed after detecting.
d. Check if the working light corresponds to the light-control.
The sensitivity is poor:
a. Please check if there is hinder in front of the detection window to effect receiving the signals.
b. Please check if the ambient temperature is too high.
c. Please check if the signals source is in the detection fields.
d. Please check if the installation height corresponds to the height showed in the instruction.
e. Please check if the moving orientation is correct.
The sensor can’t shut the load automatically:
a. Check if there are continual signals in the detection fields.
b. Check if the time setting is set to the longest.
c. Check if the power corresponds to the instruction.
d. Check if the temperature change obviously nears the sensor, such as air condition or central heating etc.
Avoid installing it near air temperature alteration zones such as air condition, central heating, etc.
Considering your safety, please don’t open the cover when you find the hitch after installation.
If there is difference between product and instruction, please refer to product mainly.
Some problem and solved way
Should be installed by electrician or experienced man.
Avoid installing it on the unrest objects.
There shouldn’t be hindrance and moving object in front of the detection window effecting detection.
Note
Adjust working light. Turn clockwise to increase it and turn anti-clockwise to decrease it.
When turn to mini, it will only work below the light-control about 10LUX, when turn to
max, it can work any light-control.
<10-2000LUX
(2)Light-control setting