Stand Alone Smoke Alarms
R
NO:LX-SI-918
LX-SI- 918 Smoke Alarm Manual
The smoke alarm adopts ionic detector, the flame and heat are not
detected, they are generally more effective at detecting fast-flaming
fires which consume combustible materials rapidly and spread quickly.
Sources of these fires may be paper burning in a wastebasket,
or a grease fire in the kitchen.
IMPORTANT! PLEASE READ CAREFULLY AND SAVE IT.
This
user
’
s manual contains important information about your smoke
alarm
’
s operation. To insure your safety, you need install one alarm at
least in your every single room. Please don
’
t open the smoke alarm
for that may cause improper effect.
SPECIFICATION
Power source:DC9V
Static Current: <10uA
Alarm Current: 10~20mA
Alarm sonority:> 85 db (3m)
Low Voltage Alarm: 7V+0.5V
Working temperature:-10
~50
WHERE TO INSTALL SMOKE ALARMS
1.
At first, you need install them in your bedroom and routeway, and
should install one item in every bedroom at least.
2.
Stairway is important for you to rush out when fires occur, so there
must install smoke detectors.
3.
You at least require one smoke alarm on every floor,including finished
attics and basements.
4.
Install one alarm beside every electric facility.
5.
Install smoke alarms in the middle of ceiling,because smog,heat and flashes always lift to the top of rooms
6.
If some reasons cause you can
’
t install them in the middle of ceiling,you need to install them at least 10cm away
from the wall.
7.
If you like to install them on the wall, they should be installed 10-30.5cm away under the ceiling. Diagram 1.
8.
You need install more than one alarm when the length of your hall exceeds 9m.
9.
In an ablique roof room,install the alarm 0.9m away from the top.Diagram 2.
10. How to install smoke alarms in a removable house.The removable house is short of heat isolation,so you
’
d better
install the alarm 10-30.5cm away from the ceiling.for safety you need install another one near your bedroom,too;
WHERE NOT TO INSTALL SMOKE ALARMS
1.
Where combustion particles are produced. Combustion particles form when something burns. Avoid installing in
BEST HERE
CEILING
1
0
C
M
(4
'')
3
0
.5
C
M
(1
2
'')
SIDE WALL
M
A
X
IM
U
M
ACCEPTABLE HERE
NEVER HERE
M
IN
IM
U
M
MINIMUM
10CM(4'')
DIAGRAM 1
IN THIS AREA
0.9M(3ft)
0.9M(3ft)
FROM PEAK
HORIZONTAL DISTANCE
ANYWGERE
DIAGRAM 2
Thank you for selecting our product LX-SI-918
℃