Stand Alone Smoke Alarms
R
LX-SO-98D
LX-SO-98D Smoke Alarm User
’
s Manual
LX98 are photoelectric smoke alarms, they are
generally more effective at detecting smoldering fires
which smolder for hours before bursting into flame.
Sources of these fires may include cigarettes burning in
couches or bedding. LX98 accords with the ISO/DIS
12239 Standard.
IMPORTANT! PLEASE READ CAREFULLY AND KEEP
IT.
This user
’
s manual contains important information
about your smoke alarm
’
s operation. To insure your
safety, you need install one alarm at least in your every
single room. Please don
’
t open the smoke alarm for that
may cause improper effect. If you are installing this smoke
alarm for use by others, you must leave this manual
–
or
a copy of it
—
with the end user.
TECHNICAL PARAMETER
DC power: Power:DC9V
Static Current: <10uA
Alarm Current:<12mA
Low Voltage Alarm: 6.5V~7.5V
AC power: Power: 110V
220V
Current:<25 mA
Alarm sonority:> 85 db (3m)
Working temperature:-10
~50
WHERE TO INSTALL SMOKE ALARMS
1. At first, you need install them in your bedroom and routeway, and should install one
item in every bedroom at least.
2. Stairway is important for you to rush out when fires occur, so there must install smoke
detectors.
3. You at least require one smoke alarm on every floor,including finished attics and
basements.
4. Install one alarm beside every electric facility.
5. Install smoke alarms in the middle of ceiling,because smog,heat and flashes always
lift to the top of rooms
6. If some reasons cause you can
’
t install them in the middle of ceiling,you need to install
them at least 10cm away from the wall.
Thank you for selecting our product LX-SO-98D
7. If you like to install them on the wall, they should be installed 10-30.5cm away under
the ceiling. Diagram 1.
8. You need install more than one alarm when the length of your hall exceeds 9m.
9. In an ablique roof room,install the alarm 0.9m away from the top.Diagram 2.
75.00mm
18.00mm
50.00mm
mm
℃