Stand Alone Smoke Alarms

 R

LX-SO-98D

10. How to install smoke alarms in a removable house.The removable house is short of

heat isolation, so you

d better install the alarm 10-30.5cm away from the ceiling.for

safety you need install another one near your bedroom, too;

WHERE NOT TO INSTALL SMOKE ALARMS

1. Where combustion particles are produced. Combustion particles form when

something burns. Avoid installing in the areas include poorly ventilated
kitchens,garages,and furnace rooms.Keep units at least 6m from the sources of
combustion particles(stove,furnace,water heater,space heater)if possible.Ventilate
these areas as much as possible.

2. In air streams near kitchens.Air currents can draw cooking smoke into the sensing

chamber of a smoke alarm near the kitchen.

3. In very damp,humid or steamy areas,or directly near bathrooms whith showers.Keep

units at least 3m away from showers saunas,dishwhashers,etc.

4. Where the temperatures are regularly below 40 F(4 C)or above 100F(38 C),including

unheated buildings,outdoor rooms,porches,or unfinished attics or basements.

5. In very dusty,dirty,or greasy areas.Don

t install a smoke alarm directly over the stove

or range.Clean a laundry room unit frequently to keep it free of dust or lint.

6. Near fresh air vents,ceiling fans,or in very drafty areas.Drafts can blow smoke away

from the unit,preventing it from reaching the sensing chamber.

7. In insect infested areas.Insects can clog openings to the sensing chamber and cause

unwanted alarms.

8. Less than 305mm away from fluorescent lights.Electrical

noise

can interfere with the

sensor.

9. In

dead air

space, for example,in Diagram 1,near the corner less than 10cm.

10. If you have a smoking meeting room, don

t install the alarm there for the unit will alarm

when several persons smoke;

BEDROOM

BASEWENT

KITCHEN

BEDROOM

SMOKE ALARM FOR ADDITIONAL PROTECTION

BEDROOM

SMOKE ALARM FOR MINIMUM PROTECTION

LIVING ROOM

BEDROOM

LI

V

IN

G

R

O

O

M

BEDROOM

SINGLE FLOOR PLAN

MULTIPLE FLOOR PLAN

KITCHEN

BEDROOM

BEST HERE

CEILING

10

C

M

(4

'')

30

.5

C

M

(1

2'

')

SIDE WALL

M

A

X

IM

U

M

ACCEPTABLE HERE

NEVER HERE

M

IN

IM

U

M

MINIMUM

10CM(4'')

DIAGRAM 1

IN THIS AREA

0.9M(3ft)

0.9M(3ft)

FROM PEAK

HORIZONTAL DISTANCE

ANYWGERE

DIAGRAM 2