background image

LX728-V1 Smoke Alarm Instruction 

The photoelectric smoke detector is designed to sense smoke that comes into the detector chamber. It does 

not sense gas, heat, or flame. This smoke detector is designed to give early warning of developing fires by 

giving off the alarm sounds from its built-in alarm horn. It can provide precious time for you and your family to 

escape before a fire spreads.

Specifications

Where to install smoke alarm

1.Install a smoke detector in the hallway outside every separate bedroom area, as shown in Figure 1.

2.Install a smoke detector on every floor of a multi-floor home or apartment, as shown in Figure2.

3.Install a smoke detector inside every bedroom.

4.Install smoke detectors at both ends of a bedroom hallway if the hallway is more than 40 feet (12 meters) long.

5.Install a smoke detector inside every room where one sleeps with the door partly or completely closed, since 

smoke could be blocked by the closed door and a hallway alarm may not wake up the sleeper if the door is closed.

6.Install basement detectors at the bottom of the basement stairwell.

7.Install second-floor detectors at the top of the first-to-second floor stairwell.

8.Install additional detectors in your living room, dining room, family room, attic, utility and storage rooms.

9.Install smoke detectors as close to the center of the ceiling as possible. If this is not practical, put the detector on 

the ceiling, no closer than 20 inches (50 cm) from any wall or corner, as shown in Figure 3.

10.If  some  of  your  rooms  have  sloped,  peaked,  or  gabled  ceilings,  try  to  mount  detectors  3  feet  (0.9  meter) 

measured horizontally from the highest point of the ceiling as shown in Figure 4.

Power source: DC9V                        

Static current: <10uA                        

Alarm current: <10mA

Low voltage alarm:7 V±0.5V

Alarm sonority:> 85 db (3m) 

AC power: Power: 100-130V/AC  

                              220-240V/AC                        

Power frequency:50/60Hz                       

Working temperature:-10°C~50°C

Figure 2

Fiure 1

smoke detector for minimum security

floor

garage

basement

kitchen

ground

bedroom

bedroom

bedroom

living room

family room

bedroom

kitchen

bedroom

bedroom

bedroom

smoke detector for minimum security

smoke detector for more security

Figure 4

Figure 3

0.9M(3ft)

horizontal distance from peak

dete

ctor

WALL

best location

acceptable location

50CM(20'')

MINIMUM

never here

CEILING

certer of ceiling

92.50mm