3-2
Service Manual
4036-402
Adjustments
Scanner calibration
This procedure should be performed whenever a new ADF assembly, internal ADF CCD
subassembly, flatbed optical unit, or main scanner card is installed.
Use this process to calibrate the grayscale adjustments in the scanner. Carefully follow the steps to
perform the calibration. The process must be completed from start to finish for successful calibration.
1.
Enter the SE menu by pressing * * 4 1 1.
2.
Select Scanner Menu from the main SE menu.
3.
Select Scan Calibration from the Scanner menu.
4.
Place the special calibration sheet facedown on the glass.
Make sure the sheet is oriented with the leading edge band to the left, as shown. Close the
document cover.
5.
Press Start.
The calibration sheet is scanned twice.
6.
Remove the sheet from the glass.