General Information 1-2
4227-100
Voltage, Ground, and Continuity Readings
Voltage Readings
All DC voltages must be 5% through -10% of the values to
be considered correct. Unless stated otherwise, all connectors
should be connected normally when a voltage measurement is
done.
When a “Line Voltage” measurement is to be done, the voltage on
United States and Canada machines should be between 100 V ac
and 127 V ac. On World Trade machines, the voltage is according to
each country’s specification.
Ground Checks
To check for a correct ground, measure the voltage between the
ground and a known good voltage source. The voltage
measurement must be the same as the source voltage to consider
the ground is correct. Continuity measurements may be used to
check grounds, however, be sure to measure to a known good
ground using the lowest ohms scale and check for zero ohms.
Note: Always unplug the power cord before doing any continuity
measurement.
Continuity Readings
When measuring continuity, be sure no back circuits affect the
measurement. If necessary, unplug connectors to remove any back
circuits. Zero the ohm range on the lowest scale (X1). An open
circuit will read infinity. A circuit with correct continuity will read zero
ohms.
Summary of Contents for 4227-100
Page 10: ...x 4227 100 Korean Safety Information...
Page 101: ...Connector Locations 5 1 4227 100 5 Connector Locations...
Page 105: ...Connector Locations 5 5 4227 100 Component Location Illustrations...
Page 106: ...5 6 4227 100 Component Location Illustrations Continued...
Page 114: ...5 14 4227 100 Connector Block Diagram...
Page 119: ...Parts Catalog 7 2 Assembly 1 Covers and Operator Panel...
Page 121: ...Parts Catalog 7 4 Assembly 2 Paper Feed...
Page 123: ...Parts Catalog 7 6 Assembly 3 Carrier...
Page 125: ...Parts Catalog 7 8 Assembly 4 Base and Electronics...
Page 127: ...Parts Catalog 7 10 Assembly 5 ASF Side Frame Covers...
Page 129: ...Parts Catalog 7 12 Assembly 6 ASF Roller Support...
Page 131: ...Parts Catalog 7 14 Assembly 7 Tractor 2 Option...