PostScript
4-26
firstside
— firstside
boolean
Indicates whether the current imaging area is on the front side of the page.
true
front side is currently being imaged
false
back side is currently being imaged
Error:
stackoverflow
fontnonzerowinding
—
boolean
fontnonzerowinding
Sets the winding rule for Type 1 fonts. No query operation is performed since the
winding rule is reset to
true
at the beginning of each print job. The Boolean
value can be:
true
non-zero winding used by the interpreter
false
even or odd winding rule used by interpreter
Error:
stackoverflow
hardwareiomode
— hardwareiomode
boolean
Queries the user default setting of the Parallel Protocol menu item. This operator
returns the value of the Parallel Protocol, either Standard or Fastbytes. An
integer
value is returned on the stack:
1
Parallel Fastbytes Off (Standard)
2
Parallel Fastbytes On (Fastbytes)
Error:
stackoverflow
idlefonts
— idlefonts
mark
Supports compatibility with the IBM LaserPrinters 4019, 4029, and 4039. It is
parsed and returns a mark on the stack.
Error:
stackoverflow