background image

 

10

_______________________________________________________________

Installation

  

Plumbing Flow Pattern for Gravity Drain: 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 
HOT AND COLD WATER SUPPLY LINES 

 

Carefully connect ½” ID supply hoses (not provided) to fresh water sources. Shut-off valves (not 
provided) should be utilized. Valves should be placed outside the tub for easy access. 
 
Before water line connections, please follow below: 
Determine if your spa chair is used for a new construction of a salon or a replacement spa chair. 

1.  New construction: Make sure to remove any and all debris and/or dust from current hot cold 

water pipes before hooking up to spa. Suggested direction to remove debris: turn on water and 
drain into a bucket or container.  See illustration below: 

    
 
 
 
 
 
 
 
 
 
 
 
2.  Replacement Spa: Always use new hot/cold water hoses when connecting a new spa chair to 

prevent debris, such as old rubber particles, from clogging drain. 

Summary of Contents for Q-SPA

Page 1: ...isprint of this advertisement Lexor s footspa specification and prices may change without prior notice Pedicure Spas are intended for professional used only always follow your State Board s sanitation...

Page 2: ...Plumbing Flow Pattern for Gravity Drain 10 Hot And Cold Water Supply Lines 10 Connectiong Drain System 11 SPA SPECIFICATION Electrical and Pedicure Spa Component Specification 12 OPERATION AND CARE O...

Page 3: ...HEY ARE CLOSELY SUPPERVISED AT ALL TIME LIRE LES INSTRUCTION DU FABRICANT AVANT DE METTRE EN MARCHE UTILISER SEULEMENT A L INTERIEUR COUPER LE COURANT AVANT DE PROCEDRE AU DEPANNAGE AU NETTOYAGE Warni...

Page 4: ...Massage Remote Control 5 Manicure Tray Optional 6 Glass Bowl 7 Footrest 8 Sani Drain System with Discharge On Off Knob 9 Dual Function Auto Fill Jet On Off Knob Upgrade Option Only 10 Hot Cold Water...

Page 5: ...5 ________________________________________________________________Installation SPA to SPA RECOMMENDED CLEARANCE Wall Clearance...

Page 6: ...___________________________________________________________Installation MANICURE TRAY ARMREST BACK REST INSTALLATION Up Down Swinging Armrest 1 Plug In the manicure trays and attach the purse hook 1 S...

Page 7: ...______________________Installation BACK REST 1 To set backrest up Lift up the backrest until a Click is heard Make sure the lever is locked before operating 2 To fold down backrest Lift up lever handl...

Page 8: ...ay void your Warranty 2 Hooking up a used Hot Cold flex hose is not recommended since debris from broken rubber seal might clog water mixer Failure to do so may void your Warranty 3 Backflow preventer...

Page 9: ...9 _______________________________________________________________Installation Gravity Drain Under Ground Plumbing Flow Pattern for Power Drain...

Page 10: ...water line connections please follow below Determine if your spa chair is used for a new construction of a salon or a replacement spa chair 1 New construction Make sure to remove any and all debris an...

Page 11: ...WITH POWER DRAIN PUMP OR GRAVITY DRAIN NO PUMP Using schedule 40 PVC Power Drain or 1 flex tube Gravity Drain and appropriate traps Connect drain to meet local plumbing codes Rubber connection to the...

Page 12: ...ed reclining massaging and sliding seat with hand held control One 1 pipe less whirlpool jet Pipe free technology Power drain or Gravity drain Extendable water spray positioned well above water line a...

Page 13: ...ter level decreases simply add more water Whirlpool Starting Turn the Jet Knob located on the right side of the front panel to clockwise to turn on Turn counterclockwise to shut off Warning Do NOT tur...

Page 14: ...sor This is because the 3 minute time out has been activated To continue filling turn the Auto Fill knob clockwise Manual conversion Auto Fill option can be simply reset to normal manual mode as a con...

Page 15: ...ase to turn off water The switch can be activated to turn on or turn off water any time during the Auto Fill cycle EXCEPT when water is at sensor level 3 To turn On Off the whirlpool jet Turn knob clo...

Page 16: ...16 _______________________________________________________Jet Cover Impeller JET COVER REMOVAL INSTALLATION 1 Turn Counterclockwise to remove Turn Clockwise to install...

Page 17: ...17 _______________________________________________________Jet Cover Impeller JET HOUSING REMOVAL INSTALLATION 1 Turn clockwise to remove motor Turn counterclockwise to install motor...

Page 18: ...ll run for duration of 20min 2 Press any button Rolling Spot Kneading Tapping Combine to enter Manual mode 3 Press Rolling Spot to stop rolling up down and stop at desired spot 4 Press Intensity butto...

Page 19: ...the back massage and secure 2 hinge screws onto the metal brackets Do not turn the screws all the way in Leave 1 4 thread screw head for sliding Install back shell with 4 screws as Fig 3 Drill 4 mount...

Page 20: ...shall be removed from the spa basin 2 The spa basin must be cleaned with soap or detergent and water 3 The spa basin must be disinfected with an EPA registered disinfectant with demonstrated bacterici...

Page 21: ...YOU MUST HAVE A QUALIFIED LICENSED PLUMBER TO CONNECT THE SPA IN PLACE SAFELY UL SAFETY RECOGNIZED FOR UNITED STATES AND CANADA LEXOR INC 14800 GOLDENWEST ST WESTMINSTER CA 92683 USA CUSTOMER CARE TE...

Reviews: