Dismantling the vehicle
The following 2 pages contain general instructions for use when working on an HS250h. Read
these instructions before proceeding to the HV battery removal instructions on page 18.
WARNING:
・
The high voltage system may remain powered for up to 10
minutes after the vehicle is shut off or disabled. To prevent
serious injury or death from severe burns or electric shock, avoid
touching, cutting, or opening any orange high voltage power
cable or any high voltage component.
1. Shut off the ignition (
READY
indicator is
off). Then disconnect the cable from the
auxiliary battery negative (-) terminal.
2. Remove the service plug grip.
(1)
Disengage the 2 clips and 2 guides, and remove the battery service hole cover.
Caution:
Wear insulated gloves for the following 3 steps.
(2) Slide the handle of the service plug grip to the left.
(3) Raise the release handle of the service plug grip.
(4) Remove the service plug grip.
(1)
(
2
)
(
3
)
(
4
)
(5) Apply insulating tape to the socket of the service plug grip to insulate it.