iPECS eMG80/100& eMG800 & UCP & vUCP
Administration and Programming Manual
Issue 2.3
255
4.4.1.7
Flexible Station Numbering Plan - PGM 105
Selecting Flexible Station Number will return the data entry page. For convenience, the copy, paste, and drag
is available to enter or modify data.
This page permits changes in the Station Numbering Plan using one of three methods:
Enter Station Index Range:
eMG80/100: 1-140 / eMG800: 1-1200 / UCP: 1-2400
Station Index Range:
use to change the station numbe
rs associated with a range of “Order
Numbers” (the indexes). The “Start Station Number” is assigned to the station with the first index then
the station number is incremented by one and assigned to the next station in the range. The process
is repeated until the station number with the last index is changed.
Station Number:
enter the station number to search. The station number is displayed and then you
can change the new station number as you wish.
Multiple Station Number to change:
there are two ways to search the station number for change;
Enter Index Range or Enter Station Range.
You can change station numbers over a range of stations using the “Start Station Number” as the first station
number for the range. The station number is incremented by one for each successive station in the range.
Figure 4.4.1.7-1 Flexible Station Number
Each iPECS IP and LDP Phone and SLT is assigned a logical order number, shown as the “Index” number on
the Web page, during the registration process. The station Index number is incremented from 1 as each
terminal device is registered.
At registration, station numbers increment sequentially with the index and are assigned starting at Station 100
for eMG80/100 and at Station 1000 for eMG800/UCP.
The Station Numbering Plan allows the station numbers to be two (2) to eight (8) digits in length as long as the
number of digits in the Station numbers is the same.