iPECS eMG80/100& eMG800 & UCP & vUCP
Administration and Programming Manual
Issue 2.3
322
Table 4.4.4.2-1 Analog ATTRIBUTES
ATTRIBUTE
DESCRIPTION
RANGE
DEFAULT
Flash Timer
This time sets the flash time.
000-300
(*10 msec)
50
Open Loop Detect
timer
This entry sets the duration of open loop that will be
recognized as a “Disconnect Signal”.
00-20
(*100
msec)
04
ICLID Ring Timer
When a call is received, the system may use ICLID (Incoming
Caller ID) to route the call. The system will delay routing a call
for this duration while awaiting ICLID. Enter a 00 to disable
ICLID routing.
00-20
(*Sec)
4
Proctor Service
Each analog CO line can be assigned to send the station
number as DTMF digits for Proctor service.
OFF
ON
OFF
Analog Line
monitor
The system can monitor and report faults on an analog CO
Line.
OFF
ON
ON
LD Inter Digit
Timer
This time is for setting the duration between digits for LD (Long
Distance) call.
00-20
(*1sec)
0
LD Pause count
This count sets the number of Pause for Long distance call.
0-10
0
Table 4.4.4.2-2 CALL METERING FUNCTION
ENTRY
SMDR METERING UNIT TYPE
00
- None
01
- 50 Hz
02
- 12 KHz
03
- 16 KHz
04
- Singular Polarity Reverse (SPR)
05
- Plural Polarity Reverse (PPR)
06
- No Polarity Reverse (NPR)